LAKE HAVASU CITY<br />

Community Services Department<br />

2330 McCulloch Blvd. North ♦ <strong>Lake</strong> <strong>Havasu</strong> <strong>City</strong>, AZ 86403<br />

SPECIAL INSPECTION CERTIFICATE<br />

_________________________________________________<br />

PROJECT NAME<br />

PERMIT NUMBER:_______________________________<br />

ADDRESS: ______________________________________<br />

_________________________________________________<br />

TRACT: _______ BLOCK: _______ LOT: _______<br />

THIS DOCUMENT MUST<br />

REMAIN AT THE CONSTRUCTION SITE<br />

VISIBLE TO ALL INSPECTORS<br />

POST ADJACENT TO<br />

THE BUILDING INSPECTION RECORD CARD<br />

<strong>Special</strong> <strong>Inspection</strong> Form Page 1 <strong>of</strong> 9 REV: 5/12


SPECIAL INSPECTION CERTIFICATE<br />

The International Building Code, Section 1704, Appendix J104.3 and the Community<br />

Services Department require that certain portions <strong>of</strong> the building construction be inspected<br />

by an approved agency in addition to the required inspections performed by the <strong>City</strong><br />

inspectors. The code stipulates that the owner or the registered design pr<strong>of</strong>essional in<br />

responsible charge acting as the owner’s agent shall employ one or more special inspectors<br />

to provide inspections during construction on the types <strong>of</strong> work listed under Section 1704.<br />

The permit applicant shall submit a statement <strong>of</strong> special inspections prepared by the<br />

registered design pr<strong>of</strong>essional in responsible charge in accordance with Section 106.1 as a<br />

condition <strong>of</strong> permit issuance. This statement shall include a complete list <strong>of</strong> materials and<br />

work requiring special inspection by Section 1704, the inspection to be performed and a<br />

list <strong>of</strong> the individuals, approved agencies or firms intended to be retained for conducting<br />

such inspections.<br />

An approved agency shall provide all information as necessary for the building <strong>of</strong>ficial to<br />

determine that the agency meets the applicable requirements. The approved agency shall<br />

be objective and competent and shall disclose possible conflicts <strong>of</strong> interest so that<br />

objectivity can be confirmed. The approved agency shall have adequate equipment to<br />

perform required tests and such equipment shall be periodically calibrated. The approved<br />

agency shall employ experienced personnel educated in conducting, supervising and<br />

evaluating tests and/or inspections.<br />

<strong>Special</strong> inspectors shall keep records <strong>of</strong> inspections. The special inspector shall furnish<br />

inspection reports to the building <strong>of</strong>ficial, and to the registered design pr<strong>of</strong>essional in<br />

responsible charge. Reports shall indicate that work inspected was done in conformance to<br />

approved construction documents. Discrepancies shall be brought to the immediate<br />

attention <strong>of</strong> the contractor for correction. If the discrepancies are not corrected, the<br />

discrepancies shall be brought to the attention <strong>of</strong> the building <strong>of</strong>ficial and to the registered<br />

design pr<strong>of</strong>essional in responsible charge prior to the completion <strong>of</strong> that phase <strong>of</strong> the work.<br />

A final report documenting required special inspections and correction <strong>of</strong> any<br />

discrepancies noted in the inspections shall be submitted at a point in time agreed upon by<br />

the permit applicant and the building <strong>of</strong>ficial prior to the start <strong>of</strong> work.<br />

<strong>Special</strong> <strong>Inspection</strong> Form Page 2 <strong>of</strong> 9 REV: 5/12


Project Name:<br />

Project Address:<br />

Community Services Department<br />

SPECIAL INSPECTION CERTIFICATE<br />

NOTIFICATION OF SPECIAL INSPECTION BY OWNER<br />

<strong>Special</strong> <strong>Inspection</strong> Form Page 3 <strong>of</strong> 9 REV: 5/12<br />

Date:<br />

As the owner <strong>of</strong> the above-mentioned project I understand that special inspection is required and I shall<br />

employ one or more approved special inspectors who will provide inspections during construction.<br />

______________________________________________<br />

Signature <strong>of</strong> Owner or Legal Agent<br />

PLEASE COMPLETE<br />

SPECIAL INSPECTIONS REQUIRED<br />

In accordance with Section 1704 <strong>of</strong> the International Building Code, I certify that I am familiar with the<br />

structural design <strong>of</strong> the above named project and I specify the following inspections/tests to be<br />

performed.<br />

________________________________________ _________________________ _____________<br />

Signature (Architect) (Engineer) Arizona Reg. No. Date<br />

Complete entire table below. Check Yes if special inspection is required per section 1704 or registrant.<br />

Check N/A if construction method is “not applicable” to project or special inspection is not required per<br />

exceptions to section 1704. (List code section and exception number in comments.)<br />

TESTING/SPECIAL INSPECTION<br />

1. STEEL CONSTRUCTION<br />

(see IBC Table 1704.3 for all required inspections)<br />

a. Structural Welding<br />

1) Structural steel<br />

2) Reinforcing steel<br />

b. High-Strength Bolting<br />

1) Bearing-type connections<br />

2) Slip-critical connections<br />

c. Steel frame joints details<br />

REQUIRED<br />

Yes [ ] N/A [ ]<br />

Yes [ ] N/A [ ]<br />

Yes [ ] N/A [ ]<br />

Yes [ ] N/A [ ]<br />

Yes [ ] N/A [ ]<br />

COMMENT


TESTING/SPECIAL INSPECTION REQUIRED COMMENT<br />

2. CONCRETE CONSTRUCTION<br />

(see IBC Table 1704.4 for all required inspections)<br />

a. Footings / Foundation<br />

b. Walls<br />

c. Bolts installed in concrete<br />

d. Shotcrete placement<br />

e. Precast erection<br />

f. Post tensioned concrete<br />

g. Prestressed concrete<br />

3. MASONRY CONSTRUCTION<br />

a. Structural masonry<br />

1) IBC Table 1704.5.1 (Nonessential facilities)<br />

2) IBC Table 1704.5.3 (Essential facilities)<br />

4. WOOD CONSTRUCTION<br />

a. Fabrication <strong>of</strong> high-load diaphragms<br />

Yes [ ] N/A [ ]<br />

Yes [ ] N/A [ ]<br />

Yes [ ] N/A [ ]<br />

Yes [ ] N/A [ ]<br />

Yes [ ] N/A [ ]<br />

Yes [ ] N/A [ ]<br />

Yes [ ] N/A [ ]<br />

Yes [ ] N/A [ ]<br />

Yes [ ] N/A [ ]<br />

Yes [ ] N/A [ ]<br />

Yes [ ] N/A [ ]<br />

5. SOILS ( IBC Table 1704.7)<br />

Required if specified by registrant or when<br />

grading involves 5000 cubic yards or more<br />

Yes [ ] N/A [ ]<br />

6. PILE FOUNDATIONS Yes [ ] N/A [ ]<br />

7. SPRAYED FIRE-RESISTANT MATERIALS Yes [ ] N/A [ ]<br />

8. EXTERIOR INSULATION AND FINISH<br />

SYSTEMS (EIFS)<br />

Yes [ ] N/A [ ]<br />

9. SMOKE CONTROL SYSTEMS Yes [ ] N/A [ ]<br />

10. SPECIAL CASES: (IBC Section 1704.13) Yes [ ] N/A [ ]<br />

11. Mechanical and Electrical Component<br />

(IBC Section 1707.8)<br />

Yes [ ] N/A [ ]<br />

ADDITIONAL LAKE HAVASU REQUIREMENTS<br />

1. BUILDING PLACEMENT SURVEY<br />

Required on all multi-family and commercial<br />

projects<br />

2. COMPACTION REPORT<br />

Minimum compaction 90% or as specified by<br />

registrant<br />

Required<br />

Yes [ ] N/A [ ]<br />

Yes [ ]<br />

Note: 1. See IBC Table 1604.5 for list <strong>of</strong> essential facilities.<br />

2. Soils report and special inspection is required for essential facilities.<br />

<strong>Special</strong> <strong>Inspection</strong> Form Page 4 <strong>of</strong> 9 REV: 5/12


SPECIAL INSPECTION RESPONSIBILITY<br />

I have assigned the following person(s) to inspect the designated work, and in accordance with Section<br />

1704 <strong>of</strong> the International Building Code as adopted, hereby assume full responsibility for the <strong>Special</strong><br />

<strong>Inspection</strong> <strong>of</strong> the following type(s) <strong>of</strong> construction.<br />

__________________________________<br />

Owner, Architect, Engineer, Agent<br />

Structural Engineer AZ Registrant No. Phone No.<br />

Architect AZ Registrant No. Phone No.<br />

Geotechnical Engineer AZ Registrant No. Phone No.<br />

Surveyor AZ Registrant No. Phone No.<br />

<strong>Special</strong> Inspector (concrete) Phone No.<br />

<strong>Special</strong> Inspector (masonry) Phone No.<br />

<strong>Special</strong> Inspector (structural steel/welding / high-strength bolting) Phone No.<br />

<strong>Special</strong> Inspector (soils testing) Phone No.<br />

<strong>Special</strong> Inspector (sprayed fire-resistant materials) Phone No.<br />

<strong>Special</strong> Inspector (EIFS) Phone No.<br />

<strong>Special</strong> Inspector (wood) Phone No.<br />

<strong>Special</strong> Inspector (specify type) Phone No.<br />

Testing Agency (soils compaction) Phone No.<br />

QUALIFICATIONS APPROVED FABRICATORS<br />

______________________________________________________ _______________________<br />

On Site Welder Cert. No. Welding Agency<br />

______________________________________________________ ______________________<br />

On Site Welder Cert. No. Truss Manufacturer<br />

______________________<br />

Pre-cast Concrete<br />

<strong>Special</strong> <strong>Inspection</strong> Form Page 5 <strong>of</strong> 9 REV: 5/12


Excerpt from 2006 International Building Code<br />

TABLE 1704.3<br />

REQUIRED VERIFICATION AND INSPECTION OF STEEL CONSTRUCTION<br />

VERIFICATION & INSPECTION<br />

1. Material verification <strong>of</strong> high-strength bolts, nuts and washers:<br />

a. Identification markings to conform to ASTM standards<br />

specified in the approved construction documents.<br />

CONTINUOUS<br />

__<br />

PERIODIC<br />

REFERENCED STANDARD a<br />

IBC<br />

REFERENCE<br />

<strong>Special</strong> <strong>Inspection</strong> Form Page 6 <strong>of</strong> 9 REV: 5/12<br />

X<br />

Applicable ASTM<br />

Material specifications; AICS 360,<br />

Section A3.3<br />

b. Manufacturer’s certificate <strong>of</strong> compliance required. __ X _ __<br />

2. <strong>Inspection</strong> <strong>of</strong> high-strength bolting:<br />

a. Bearing-type connections. __ X AISC 360 Section M2.5 1704.3.3<br />

b. Slip-critical connections. X X<br />

3. Material verification <strong>of</strong> structural steel:<br />

a. Identification markings to conform to ASTM standards<br />

specified in the approved construction documents.<br />

__<br />

__<br />

ASTM A 6 or ASTM A 568<br />

b. Manufacturers’ certified mill test reports. __ __ ASTM A 6 or ASTM A 568<br />

4. Material verification <strong>of</strong> weld filler materials:<br />

a. Identification markings to conform to AWS specification<br />

in the approved construction documents.<br />

__ __ AISC 360, Section A3.5;<br />

__<br />

b. Manufacturer’s certificate <strong>of</strong> compliance required. __ __ __ __<br />

5. <strong>Inspection</strong> <strong>of</strong> welding:<br />

a. Structural steel:<br />

__ __<br />

1) Complete and partial penetration groove welds. X __<br />

2) Multi-pass fillet welds. X __<br />

3) Single-pass fillet welds > 5/16” X __<br />

4) Single-pass fillet welds < 5/16” __ X<br />

AWS D1.1<br />

5) Floor and deck welds. __ X AWS D 1.3 __<br />

b. Reinforcing Steel: __ __<br />

1) Verification <strong>of</strong> weldability <strong>of</strong> reinforcing steel other<br />

than ASTM A 706.<br />

2) Reinforcing steel-resisting flexural and axial forces in<br />

__ X<br />

intermediate and special moment frames, and<br />

boundary elements <strong>of</strong> special reinforced concrete<br />

shear walls and shear reinforcement.<br />

X<br />

__<br />

3) Shear reinforcement. X __<br />

4) Other reinforcing steel. __ X<br />

6. <strong>Inspection</strong> <strong>of</strong> steel frame joint details for compliance with<br />

X<br />

approved construction documents:<br />

a. Details such as bracing and stiffening.<br />

__<br />

__<br />

b. Member locations.<br />

__<br />

__<br />

c. Application <strong>of</strong> joint details at each connection.<br />

__<br />

__<br />

For SI: 1 inch = 25.4 mm.<br />

a. Where applicable, see also Section 1707.1, <strong>Special</strong> <strong>Inspection</strong> for seismic resistance.<br />

AWS D1.4<br />

ACI 318: 3.5.2<br />

__<br />

__<br />

1708.4<br />

1704.3.1<br />

1704.3.2


Excerpt from 2006 International Building Code<br />

TABLE 1704.4<br />

REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION<br />

VERIFICATION & INSPECTION<br />

1. <strong>Inspection</strong> <strong>of</strong> reinforcing steel, including<br />

prestressing tendons, and placement.<br />

2. <strong>Inspection</strong> <strong>of</strong> reinforcing steel welding in<br />

accordance with Table 1704.3, Item 5B.<br />

3. Inspect bolts to be installed in concrete prior to<br />

and during placement <strong>of</strong> concrete where<br />

allowable loads have been increased.<br />

4. Verifying use <strong>of</strong> required design mix.<br />

5. At the time fresh concrete is sampled to fabricate<br />

specimens for strength tests, perform slump and<br />

air content tests, and determine the temperature<br />

<strong>of</strong> the concrete.<br />

6. <strong>Inspection</strong> <strong>of</strong> concrete and shotcrete placement<br />

for proper application techniques.<br />

7. <strong>Inspection</strong> for maintenance <strong>of</strong> specified curing<br />

temperature and techniques.<br />

8. <strong>Inspection</strong> <strong>of</strong> prestressed concrete:<br />

a. Application <strong>of</strong> prestressing forces.<br />

b. Grouting <strong>of</strong> bonded prestressing tendons in<br />

the seismic-force-resisting system.<br />

9. Erection <strong>of</strong> precise concrete members.<br />

10. Verification <strong>of</strong> in-situ concrete strength, prior<br />

to stressing <strong>of</strong> tendons in post-tensioned<br />

concrete and prior to removal <strong>of</strong> shores and<br />

forms from beams and structural slabs.<br />

11. Inspect form work for shape, location, and<br />

dimensions <strong>of</strong> concrete member being formed.<br />

CONTINUOUS<br />

__<br />

__<br />

PERIODI<br />

C<br />

For SI: 1 inch – 25.4mm.<br />

a. Where applicable, see also Section 1707.1, <strong>Special</strong> <strong>Inspection</strong> for seismic resistance.<br />

X<br />

__<br />

X<br />

X<br />

__<br />

X<br />

X<br />

REFERENCED<br />

STANDARD a<br />

IBC REFERENCE<br />

<strong>Special</strong> <strong>Inspection</strong> Form Page 7 <strong>of</strong> 9 REV: 5/12<br />

X<br />

__<br />

__<br />

ACI 318: 3.5, 7.1-7.7<br />

AWS D1.4<br />

ACI 318: 3.5.2<br />

__<br />

1913.4<br />

__<br />

1911.5<br />

X ACI 318: Ch.4, 5.2-5.4 1904.2.2, 1913.2, 1913.3<br />

__<br />

__<br />

X<br />

__<br />

ASTM C 172<br />

ASTM C 31<br />

ACI 318: 5.6, 5.8<br />

ACI 318: 5.9, 5.10<br />

ACI 318: 5.11-5.13<br />

ACI 318: 18.20<br />

ACI 318: 18.18.4<br />

1913.10<br />

1913.6, 1913.7, 1913.8<br />

1913.9<br />

__ X ACI 318: Ch. 16 __<br />

__<br />

X<br />

ACI 318: 6.2<br />

__ X ACI 318:6.1.1 __<br />

__<br />

__


Excerpt from 2006 International Building Code<br />

INSPECTION TASK<br />

1. As masonry construction begins, the following shall be<br />

verified to ensure compliance:<br />

a. Proportions <strong>of</strong> site-prepared mortar.<br />

TABLE 1704.5.1<br />

LEVEL 1 SPECIAL INSPECTION (Masonry)<br />

FREQUENCY OF<br />

INSPECTION<br />

Continuous Periodically<br />

during task during task<br />

listed<br />

listed<br />

IBC<br />

Section<br />

REFERENCE FOR CRITERIA<br />

ACI 530/ASCE<br />

5/TMS 402 a<br />

ACI 530.1/ASCE<br />

6/TMS 602 a<br />

b. Construction <strong>of</strong> mortar joints. __<br />

X __<br />

__<br />

Art. 3.3B<br />

<strong>Special</strong> <strong>Inspection</strong> Form Page 8 <strong>of</strong> 9 REV: 5/12<br />

X<br />

Art. 2.6A<br />

c. Location <strong>of</strong> reinforcement and connectors. X Art. 3.4, 3.6A<br />

d. Prestressing technique. __ X __ __ Art. 3.6B<br />

e. Grade and size <strong>of</strong> prestressing tendons and anchorges.<br />

2. The inspection program shall verify:<br />

__ X __ __ Art. 2.4B, 2.4H<br />

a. Size and location <strong>of</strong> structural elements. __ X __ __ Art. 3.3G<br />

b. Type, size and location <strong>of</strong> anchors, including other details<br />

<strong>of</strong> anchorage <strong>of</strong> masonry to structural members, frames or<br />

other construction..<br />

__<br />

X<br />

__<br />

Sec. 1.2.2(e),<br />

2.1.4, 3.1.6<br />

c. Specified size, grade and type <strong>of</strong> reinforcement. __ X __ Sec. 1.13 Art. 2.4, 3.4<br />

d. Welding <strong>of</strong> reinforcing bars. X __ __ Sec. 2.1.10.7.2,<br />

3.3.3.4(b)<br />

__<br />

e. Protection <strong>of</strong> masonry during cold weather (temperature<br />

below 40 o F) or hot weather (temperature above 90 o F).<br />

__ X Sec. 2104.3, 2104.4 __ Art. 1.8C, 1.8D<br />

f. Application and measurement <strong>of</strong> prestressing force. __ X __ __ Art. 3.6B<br />

3. Prior to grouting, the following shall be verified to ensure<br />

compliance:<br />

a. Grout space is clean.<br />

b. Placement <strong>of</strong> reinforcement, connectors, prestressing<br />

tendons, and anchorages.<br />

c. Proportions <strong>of</strong> site-prepared grout and prestressing grout<br />

for bonded tendons.<br />

__<br />

X<br />

X<br />

X<br />

__<br />

__<br />

__ Art. 3.2D<br />

Sec. 1.13<br />

__<br />

Art. 3.4<br />

Art. 2.6B<br />

d. Construction <strong>of</strong> mortar joints. X __ Art. 3.3B<br />

4. Grout placement shall be verified to ensure compliance with<br />

code and construction document provisions.<br />

X __ __ __ Art. 3.5<br />

a. Grouting <strong>of</strong> prestressing bonded tendons. X __ __ __ Art. 3.6C<br />

5. Preparation <strong>of</strong> any required grout specimens, mortar<br />

X __ Sec. 2105.2.2,<br />

__ Art. 1.4<br />

specimens and/or prisms shall be observed.<br />

2105.3<br />

6. Compliance with required inspection provisions <strong>of</strong> the<br />

construction documents and the approved submittals shall be<br />

verified.<br />

__<br />

X<br />

__<br />

__<br />

Art. 1.5<br />

For SI: o C = ( o F – 32)/1.8.<br />

a. The specific standards referenced are those listed in Chapter 35.


Excerpt from 2006 International Building Code<br />

INSPECTION TASK<br />

1 From the beginning <strong>of</strong> masonry construction, the following<br />

shall be verified to ensure compliance:<br />

a. Proportions <strong>of</strong> site-prepared mortar, grout and prestressing<br />

grout for bonded tendons.<br />

b. Placement <strong>of</strong> masonry units and construction <strong>of</strong> mortar<br />

joints..<br />

c . Placement <strong>of</strong> reinforcement, connectors and prestressing<br />

tendons and anchorages.<br />

TABLE 1704.5.3<br />

LEVEL 2 SPECIAL INSPECTIONS (Masonry)<br />

FREQUENCY OF<br />

INSPECTION<br />

Continuous Periodically<br />

during task during task<br />

listed<br />

listed<br />

__<br />

__<br />

__<br />

IBC<br />

Section<br />

REFERENCE FOR CRITERIA<br />

ACI 530/ASCE<br />

5/TMS 402 a<br />

ACI 530.1/ASCE<br />

6/TMS 602 a<br />

<strong>Special</strong> <strong>Inspection</strong> Form Page 9 <strong>of</strong> 9 REV: 5/12<br />

X<br />

X<br />

X<br />

__<br />

__<br />

__<br />

__<br />

__<br />

Sec. 1.13<br />

Art. 2.6A<br />

Art.3.3B<br />

Art. 3.4, 3.6A<br />

d. Grout space prior to grouting.. X __ __ __ Art. 3.2D<br />

e. Placement <strong>of</strong> grout.<br />

f. Placement <strong>of</strong> prestressing grout.<br />

2. The inspection program shall verify:<br />

X __ __ __ Art. 3.5<br />

X __ __ __ Art. 3.6C<br />

a. Size and location <strong>of</strong> structural elements. __ X __ __ Art. 3.3G<br />

b. Type, size and location <strong>of</strong> anchors, including other details<br />

<strong>of</strong> anchorage <strong>of</strong> masonry to structural members, frames or<br />

other construction.<br />

X<br />

__<br />

__<br />

Sec. 1.2.2(e),<br />

2.1.4, 3.1.6<br />

c. Specified size, grade and type <strong>of</strong> reinforcement. X __ Sec. 1.13 Art. 2.4, 3.4<br />

d. Welding <strong>of</strong> reinforcement.<br />

e. Protection <strong>of</strong> masonry during cold weather (temperature<br />

X __ __ Sec. 2.1.10.7.2,<br />

3.3.3.4(b)<br />

below 40 o F) or hot weather (temperature above 90 o F).<br />

__<br />

X Sec. 2104.3, 2104.4 __<br />

__<br />

__<br />

Art. 1.8C, 1.8D<br />

f. Application and measurement <strong>of</strong> prestressing force. X __ __ __ Art. 3.6B<br />

3. Preparation <strong>of</strong> any required grout specimens, mortar specimens<br />

and/or prisms shall be observed.<br />

4. Compliance with required inspection provisions <strong>of</strong> the<br />

construction documents and the approved submittals shall be<br />

verified.<br />

For SI: o C = ( o F – 32)/1.8.<br />

a. The specific standards referenced are those listed in Chapter 35.<br />

X __ Sec. 2105.2.2,<br />

__<br />

X<br />

2105.3<br />

__<br />

__<br />

__<br />

Art. 1.4<br />

Art. 1.5