10.07.2015 Views

sma ultra compact and expanded ultra compact provisioning control ...

sma ultra compact and expanded ultra compact provisioning control ...

sma ultra compact and expanded ultra compact provisioning control ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Prepared (also subject responsible if other)Ericssonwide InternalDIMENSIONING RULESETL/G/S Peter Barwick 192 02-FGC 101 901Approved Checked Date Rev ReferenceETL/G/S Karl-Eric K Malberg 16/02/2006 BNo.OMS 1200 FamilyR3.xCompatibility <strong>and</strong>Composition RulesAbstract:INFORMATION FOR ERICSSON USERNote from Product Management:This document (not to be issued to customers) provides visibility of the OMS 1200 FamilyComposition Rules for R3.x. This document should be used in conjunction with the Provisioning<strong>and</strong> Control Document to generate a ‘Bill of Quantities’ for Customer Solutions. The BOQ will be alist of Marconi Saleable Entity Codes (SE).Both Hardware <strong>and</strong> Software are purchased using Marconi SE CodesMarconi is part of the Ericsson group. The Ericsson Optical Network is a transport network portfolio provided inconjunction with Marconi. It includes SDH <strong>and</strong> DWDM NE’s <strong>and</strong> a common NMS system.The portfolio is both broad <strong>and</strong> complete.


SMA1/4/16 UC & EX - PROVISIONING CONTROL DOCUMENTSMA ULTRA COMPACT ANDEXPANDED ULTRA COMPACTPROVISIONING CONTROLDOCUMENTThis is a Marconi CommunicationsSpecification authorised for use by:Nick KingsSMA1/4/16 Engineering ManagerAC4521Product EngineeringBeestonThe information contained herein is theresponsibility of <strong>and</strong> is approved by thefollowing, to whom all enquiries should bedirected in the first instance:Jon KnightSMA1/4/16UC/EX Product ChampionAC4521Product EngineeringBeestonDave NettletonSMA1/4/16UC/EX Product ChampionAC4521Product EngineeringBeestonThis is an unpublished work the copyright in which vests in Marconi Communications Limited. All rights reserved.The information contained herein is confidential <strong>and</strong> the property of Marconi Communications Limited <strong>and</strong> is supplied without liability forerrors or omissions. No part may be reproduced, disclosed or used except as authorised by contract or other written permission. The copyright<strong>and</strong> the foregoing restriction on reproduction <strong>and</strong> use extend to all media in which the information may be embodied.1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 01Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT0.1 CONTENTS0.1 CONTENTS.................................................................................................................................................20.2 HISTORY ....................................................................................................................................................40.3 ISSUE CONTROL.......................................................................................................................................50.4 REFERENCES.............................................................................................................................................50.5 GLOSSARY OF TERMS.............................................................................................................................61 INTRODUCTION ......................................................................................................................................1012 OVERVIEW OF THE PRODUCT ...........................................................................................................2012.1 SMA1/4UC ..............................................................................................................................................2012.2 SMA1/4EX...............................................................................................................................................2032.3 SMA1/4/16UC/EX...................................................................................................................................2032.4 NETWORK MANAGEMENT ................................................................................................................2042.5 EXPORT LICENCE ................................................................................................................................2043 UC PRODUCT STRUCTURE ..................................................................................................................3013.1 EQUIPING/CONFIGURATION RULES................................................................................................3023.2 SALEABLE ENITITIES..........................................................................................................................3034 EX PRODUCT STRUCTURE...................................................................................................................4014.1 EQUIPING/CONFIGURATION RULES...........................................................................................................4014.2 SALEABLE ENITITIES .................................................................................................................................4075 SMA ULTRA COMPACT AND EXTENDED ULTRA COMPACT (UC & EX) SALEABLEENTITIES.............................................................................................................................................................5015.1 CORE SYSTEM ......................................................................................................................................5015.2 ITEMS ASSOCIATED WITH THE CORE .............................................................................................5045.3 SFP TRIB & LINE INTERFACES ..........................................................................................................5065.4 2MBIT/S TRIBUTARY INTERFACES..................................................................................................5065.5 GENERIC TRIBUTARY CARDS...........................................................................................................5105.6 COMMS/AUX/ANCILLARY CARD SP53B .........................................................................................5145.7 EMC COVERS ........................................................................................................................................5145.8 BACKUP AND LCT S/W........................................................................................................................5155.9 MISCELLANEOUS ................................................................................................................................5155.10 SPARES SP97**.................................................................................................................................5160.1 SMA UC AC POWER & BATTERY BACKUP......................................................................................5175.11 ....................................................................................................................................................................5176 TRAFFIC INTERFACES..........................................................................................................................6016.1 LINE SLOTS............................................................................................................................................6016.2 OPTICAL TRIBUTARY CARDS ...........................................................................................................6016.3 ELECTRICAL TRIBUTARY CARDS (FRONT PANEL ACCESS)......................................................6036.4 ELECTRICAL TRIBUTARY CARDS (LTU ACCESS).........................................................................6047 NON-TRAFFIC EXTERNAL INTERFACES.........................................................................................7017.1 POWER/LCT LTU INTERFACES..........................................................................................................7017.2 COMMS/AUX/ANCILLARY CARD INTERFACES ............................................................................7027.3 AC POWER & BATTERY BACKUP UNIT.....................................................................................................7048 MONITOR POINTS & TEST BUS ..........................................................................................................8018.1 34/45MBIT/S ...........................................................................................................................................8018.2 140/155MBIT/S .......................................................................................................................................8018.3 CONVENTIONAL STM-1 OPTICAL ....................................................................................................8018.4 DUAL STM-1 OPTICAL AND QUAD STM-1 OPTICAL/ELECTRICAL............................................8018.5 CONVENTIONAL STM-1 ELECTRICAL.............................................................................................8028.6 DUAL STM-1 ELECTRICAL .................................................................................................................8021ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 2Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT8.7 2MBIT/S TESTBUS ................................................................................................................................8029 COMMUNICATIONS ...............................................................................................................................9019.1 IS-IS TABLE SPACE ..............................................................................................................................90110 AUXILLARY AND ANCILLARY FUNCTIONALITY.......................................................................100110.1 COMMS/AUXILIARY/ANCILLARY CARD (SP53B) ..................................................................100110.2 EXTERNAL EOW UNIT (SP52A)...................................................................................................100211 LOCAL TERMINAL AND ELEMENT SOFTWARE .........................................................................110111.1 LCT HARDWARE ...........................................................................................................................110111.2 LCT & BACKUP SOFTWARE ........................................................................................................110211.3 LCT OPERATING SYSTEM ...........................................................................................................110211.4 NETWORK ELEMENT SOFTWARE .............................................................................................110211.5 CELLSPAN CARDS.........................................................................................................................110311.6 PACKETSPAN CARDS ...................................................................................................................110311.7 LAYER 2 CARDS.............................................................................................................................110312 CARD FACIA ...........................................................................................................................................120113 EMC COVERS .........................................................................................................................................130113.1 UNEQUIPPED SLOT COVERS.......................................................................................................130114 MECHANICAL DETAILS......................................................................................................................140114.1 SUBRACK MOUNTING..................................................................................................................140114.2 UNIT DIMENSIONS........................................................................................................................140114.3 WEIGHTS.........................................................................................................................................140214.4 RECOMMENDED RACKS FOR HOUSING SMA SUBRACKS/UNITS ......................................140314.5 OPTICAL FIBRE AND CABLE DRESSING...................................................................................140314.6 SUBRACK INSTALLATION ..........................................................................................................140315 RECOMMENDED CABLES, CONNECTORS, CABLE ASSEMBLIES AND KITS OF PARTS..150115.1 RECOMMENDED CABLES............................................................................................................150115.2 PRE MADE CABLE ASSEMBLIES ................................................................................................150415.3 CONNECTOR KITS OF PARTS......................................................................................................150616 POWER CONSUMPTION AND EQUIPMENT PROTECTION .......................................................160116.1 POWER CONSUMPTION FIGURES..............................................................................................160116.2 TYPICAL POWER CALCULATION ..............................................................................................160216.3 EXTERNAL PROTECTIVE DEVICE (EPD) ..................................................................................160216.4 MULTIPLE SUBRACK MOUNTING .............................................................................................160417 RELIABILITY..........................................................................................................................................170117.1 SMA CARD MTBF PREDICTIONS ................................................................................................170118 STANDARDS AND APPROVALS .........................................................................................................180118.1 ENVIRONMENTAL SPECIFICATION ..........................................................................................180118.2 SAFETY............................................................................................................................................180118.3 REPORTS .........................................................................................................................................18021ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 3Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT0.2 HISTORYChange No. Iss Details Of ChangeueN/A 1a First Draft IssueAuthor: Name Andy HargreavesDepartment AC4521Site BeestonN/A 1 First issue. Changes incorporated after review of issue 1a.Author: Name Andy HargreavesDepartment AC4521Site BeestonECN6031022 2 SE codes added for SFPs (+ description change)Bracket information changed1.5M References removedEMC ME <strong>and</strong> SE codes addedIPS table addedAuthor: Name Andy HargreavesDepartment AC4521Site BeestonECN6031823 3 Following SE codes added:-SFP-E140M Trib & LTUSTM-1e Trib <strong>and</strong> LTURelease 3 Backup S/W <strong>and</strong> LCT CD-ROMEOWBlank Optical Module KOPLCT (Windows 2000)LCT (Windows XP)Following SEs modified:-SMA1/4UC CoreHorizontal mounting/Cooling assemblySTM-1 Optical line ModulesGeneric Trib EMC Cover140M Gen Trib Front access45M Trib <strong>and</strong> LTUDIN Options removedFollowing SEs removed:-SMA LCT SoftwareSU65AASN64CFSP65TASP81CSP52ASP73ANH40FNH40GSP03ASP03BSU66**/SU67**SP73EASN64CESP63ASN44AA/AC/AE/AG/AHSA80AVarious text updated.Weights, MTBF <strong>and</strong> dimensions added for UC unitsSection 14 (recommended cabling) text removedAuthor: Name Andy Hargreaves1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 4Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTDepartment AC4521Site BeestonECN6032549 4 Extensive Saleable entity structure/code changes.Separate CQA document created which will be used as the authority on SaleableEntities.Main text changes.Section 19 (SE structures removed) <strong>and</strong> references to CQA (StructuresDocument) added.Section 14 text added (previously just had a title)Section 10 Extensively updated (Software) <strong>and</strong> details from previous section 18(now deleted) incorporated.Author: Name Andy HargreavesDepartment AC4521Site BeestonECN6033263 5 New issue to add EX configuration information.Section 2 updated slightly to introduce EX sub-rack <strong>and</strong> STM-4/16 Core.Section 4 – “EX Product Structure” added to give details of EX configurationrules.Section 5 – “SMA Ultra Compact <strong>and</strong> Extended Ultra Compact (UC & EX)Saleable Entities” updated to add new EX SEs.6 Updates for R3.3.1 Product Release:7 Core SEs updated to remove s/w on CF card - must now be ordered separately.New UC Cores SP03AC & SP13AC introduced with PWR/LCT LTU removed.New PWR/LCT LTU SEs SP03DA & SP03DB introduced for use with SP03AC& SP13AC from Q1 2006.Fan Tray removed from SMA16EC & EX SEs <strong>and</strong> equipping rules updated.EX Power Feed Protection LTU SE SP97AD replaced by SP20D.Comms/Aux/Ancillary in SP53B replaced by Enhanced Comms/Aux/Ancillary.2M Trib SE SP60C now calls up 2M card Version 2.SMA UC AC Power & Battery Backup SEs introduced0.3 ISSUE CONTROLDate 21Mar200325Apr200309June200303Nov200313Sep200404Nov200429Nov200417May2005SectionAll 1a 1 2 3 4 5A 5 6 704Nov20050.4 REFERENCES0.5.1 1QDE10274AAU-YYA Installation Guide for SDH Transmission Equipment.0.5.2 1ADA61787AAF-BTA Architecture Specification for SMA1/4 UC0.5.3 1AFB60007AAJ-YBA Netguide – Optical Budget Data0.5.4 1QDA60005ACM-YYA Marketing Export Controls Procedure Spec0.5.5 1QAA20148AAW-YYA Generic Hardware Procurement Specification0.5.6 EN50082-1 European St<strong>and</strong>ard (Class B - EN55022)1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 5Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT0.5.7 ETS 300 019-2 Equipment Engineering (EE):EuropeanTelecommunications St<strong>and</strong>ard for Equipment Practice;Engineering Requirements for Subracks in misc Racks<strong>and</strong> Cabinets0.5.8 EN 300 386-2 European St<strong>and</strong>ard:Equipment Engineering Telecommunication NetworkEquipment Electromagnetic RequirementsPart 2 Product Specific Compliance Criteria <strong>and</strong>Operating Conditions0.5.9 ES 201 468 Enhanced Availability of Service Level0.5.10 ETS 300 132-2 Equipment Engineering (EE):Power Supply Interface atthe input to Telecommunications Equipment0.5.11 BTR 2511 British Telecommunications Requirements forTelecommunication Power Requirements0.5.12 EN 60950 European St<strong>and</strong>ard: Safety of Information TechnologyEquipment including Electrical Business Equipment0.5.13 EN 60825-1 European St<strong>and</strong>ard: Safety of Laser Products0.5.14 1ADR60693AAB-CTA Series 4 SMA Provisioning Control Document0.5.15 1ADR60773AAC-CQA SMA UC Structures <strong>and</strong> Rules Document0.5.16 1ADR60674AAX-CTA Provisioning Control Document for ETSI Rack <strong>and</strong>Associated Parts0.5.17 03ADR00001AAF-CTA Packetspan II Product Provisioning Control Document0.5 GLOSSARY OF TERMSADM Add Drop MultiplexerATM Asynchronous Transfer ModeAUI Adaption Unit InterfaceCF Compact FlashDFW Dual Fibre WorkingETA Ethernet Traffic AdapterLCT Local craft terminalLTU Line termination unitMM MultimodeMTBF Mean time between failuresPSU Power supply unitSDH Synchronous digital hierarchySFW Single Fibre WorkingSMA1/4UC SMA1/4 Ultra CompactSTM-1/4 Synchronous transport moduleVC Virtual containerVC-12 Virtual container level (12)VCAM Virtual container access moduleVCTS Virtual container transport systemME Manufacturable EntitySE Saleable EntityEnd of section1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 6Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT1 INTRODUCTIONThis document specifies the <strong>provisioning</strong> <strong>and</strong> <strong>control</strong> rules for the Marconi CommunicationsSMA1/4 Ultra Compact Product.The purpose of this document is to enable sales, commercial <strong>and</strong> planning to provision theproduct into SDH networks.End of Section1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 101Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT2 OVERVIEW OF THE PRODUCT2.1 SMA1/4UCThe SMA1/4UC is a full feature ADM, optimized for both SDH ring <strong>and</strong> terminal applications.The product is intended for applications requiring high volume 2Mbit/s transport at STM-1, forlight traffic STM-4 applications that require the flexibility <strong>and</strong> protection options provided by aSIU sub-rack format. The equipment is also targeted for use in street/radio cabinets. It offers aflexible range of service deliveries including Ethernet. The product is also ideal for multitenantedbuildings; it has the capacity to serve multiple businesses whilst minimizing spacerequirements.It provides delivery of STM-1/4 SDH functionality to the customer together with SDH ring <strong>and</strong>protected terminal applications through two line interfaces.The SMA1/4UC can be deployed in mobile radio networks for the collection <strong>and</strong> consolidationof traffic from radio base stations. The product has an extremely <strong>sma</strong>ll footprint <strong>and</strong> flexiblemounting options, vertical or horizontal, makes effective use of space.The SMA1/4UC is designed <strong>and</strong> built on the highly successful SMA <strong>and</strong> MSH product range.This will complement these products which are already deployed extensively in SDH AccessNetworks (in street cabinets, local exchanges <strong>and</strong> directly on customer premises). TheSMA1/4UC can be deployed in networks with the existing Marconi SDH products. They canbe used in mixed rings with <strong>and</strong> subtended from the existing ADMs.The SMA1/4UC is managed by Marconi’s Network Management, MV38, the ElementManagement system, MV36, or by a local terminal.2.1.1 Main Features• Next generation SDH Add/Drop Multiplexer with full, non-blocking, VC-12 crossconnection capability.• Compatible with the Marconi Corporations range of synchronous multiplexers.• Two Line interfaces supporting ring <strong>and</strong> protected terminal applications.• Support of SNCP <strong>and</strong> 1+1 MSP traffic protection.• STM-1 (155 Mbit/s) <strong>and</strong> STM-4 (622 Mbit/s) aggregate options.• Full, non-blocking, VC-12 cross connect capabilityTraffic ports:• 2Mbit/s, 34Mbit/s, 45Mbit/s, STM-1 (optical <strong>and</strong> electrical), STM-4• Ethernet 10 BaseT & 100 BaseT• Support of I.421 for primary rate ISDN.• TCM for termination of inter-operator paths.1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 201Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT• Comprehensive configuration, fault <strong>and</strong> performance management features.• Compact design, suitable for customer premises, meeting Class B EMC requirements.• 4 port STM-1/4 multi-rate card with SFP modules offering flexibility <strong>and</strong> a full range ofoptical <strong>and</strong> electrical interfaces.2.1.2 Add/Drop-Based ApplicationsConventional SDH Add/Drop Multiplexers, designed for rack mounting in a network-operatorenvironment, are being deployed in increasing numbers to deliver services to businesscustomers with high b<strong>and</strong>width <strong>and</strong> high Quality of Service (QoS) requirements. TheSMA1/4UC allows the operator to target the next tier of <strong>sma</strong>ll <strong>and</strong> medium businesscustomers, with a cost-effective solution designed specifically around customer-premisesrequirements in terms of environment <strong>and</strong> capacity.The SMA1/4UC can be deployed, as Network Termination Equipment (NTE), on customerpremises. Applications include campus rings <strong>and</strong> multi-tenanted buildings. It will be deployedeither as a terminal, in hubbing architectures, or as a ring based ADM. Traffic protection maybe employed for both these applications, either 1+1 Multiplex Section Protection (MSP) or SubNetwork Connection Protection (SNCP). The solution brings the major benefits associated withSDH delivery into the customer premises.Core NetworkMSH/SMAMSH/SMACustomer PremisesSMA1/4cSMA1/4 UCSMA1/4 UC +PacketSpanSMA1/4 UCFigure 2.1Network ConfigurationsThe product will also be deployed in mobile radio networks for the collection <strong>and</strong> consolidationof traffic from radio base stations. Other applications will see the SMA1/4UC deployed withinthe access network, particularly in street side cabinets.1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 202Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTExample applications include telephony where the product will be deployed alongside PrimaryMultiplexers, delivering narrow-b<strong>and</strong> services to residential customers.The SMA1/4UC is designed to meet the ETSI <strong>and</strong> UK st<strong>and</strong>ards for Class B EMC, togetherwith climatic, safety <strong>and</strong> regulatory st<strong>and</strong>ards appropriate to this environment.2.1.3 Point to Point ApplicationsAlthough intended as a solution for integration within an SDH Network, the SMA1/4UC canalso be used for point to point systems. This configuration can be used to support up to 63 x 2Mbit/s for services such as 2 Mbit/s leased lines, direct connection to PBX’s <strong>and</strong> data.2.2 SMA1/4EXThe SMA1/4EX is a larger version of the SMA1/4UC offering equivalent functionality to theSMA1/4UC <strong>and</strong> the following extra features:• Maximum capacity of 252 x 2Mbit/s balanced tributary access within the sub-rack.• Maximum capacity of 126 x 2Mbit/s unbalanced tributary access within the sub-rack. (252x 2Mbit/s unbalanced can be provided using balanced LTUs <strong>and</strong> external balancedunbalancedconversion).• 1:N 2 Mbit/s protection.• Three generic tributary slots each having 2 x STM-1 b<strong>and</strong>width.• Two generic tributary slots each having 4 x STM-1 b<strong>and</strong>width.• Duplicated power LTU.2.3 SMA1/4/16UC/EX2.3.1 STM-4/16 Core UnitThe SMA1/4UC/EX uses the STM-1/4 Core/CCU unit.A new type of Core/CCU provides unduplicated STM-4/16 interfaces. This unit will be useablein both UC <strong>and</strong> EX sub-racks <strong>and</strong> provide upgrade to STM-16 aggregate line rate.The SMA4/16UC/EX will operate in the same way as the SMA1/4UC/EX with the followingexceptions.• Two-fibre MS-SPRING at STM-4 <strong>and</strong> STM-16 line rates can be provided.• The STM-4/16 Core/CCU has only one bi-directional STM-4/16 interface per unit thereforeMSP operation is not provided.• Two further generic tributary slots, each having 4 x STM-1 b<strong>and</strong>width, are available.1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 203Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT2.3.2 SMA1/4/16 <strong>and</strong> UC/EX OptionsThere will be four basic configurations of the product.• SMA1/4UC• SMA1/4EX• SMA4/16UC• SMA4/16EXUC sub-rack with STM-1/4 Core/CCU card.EX sub-rack with STM-1/4 Core/CCU card.UC sub-rack with STM-4/16 Core/CCU card.EX sub-rack with STM-4/16 Core/CCU card.Note that the EX version of sub-rack will only support the following STM-1/4 tributary cards.• 4 Port STM-1/4 multi-rate card (with SFP modules).• 2 port fixed STM-1 electrical interface (required for STM-1 operation with card protection).• STM-4 VC-4 C/V contiguous to virtual concatenation conversion tributary.2.4 NETWORK MANAGEMENTThe Network Management is via the Marconi Network Management System, MV38.The network management information is carried over a DCC channel contained in the SDHSection Overhead (SOH). From R3.4 rev it is also possible to transport a DCC channel via a2Mbit/s port using the Enhanced Comms/Aux/Ancillary card, please refer to section 10.1 forfull details.The SOH also provides an auxiliary channel for the transport of network managementinformation for co-located equipment from Marconi Communications or third party equipment.Management of the SMA1/4/16UC/EX is via the Marconi Element Management System,MV36, <strong>and</strong>/or the LCT.The equipment management operations systems utilize Marconi st<strong>and</strong>ard workstation terminal,for providing management <strong>and</strong> <strong>control</strong> of the element.Software download may be achieved from the LCT, or from the Element Manager MV36.2.5 EXPORT LICENCEIt is the business’ responsibility to ensure that an appropriate export licence covers anyequipment manufactured or procured for export. In most cases, it is sufficient to use an Opengeneral export licence (OGEL) for that equipment that do not employ any <strong>control</strong>led items intheir manufacture. Where <strong>control</strong>led items are employed, an application for an individuallicence must be applied for before exports can be permitted. Refer to the Marketing ExportControls Procedure specification, 1QDA 60005 ACM-YYA if guidance is required.End of section1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 204Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT3 UC PRODUCT STRUCTUREFigure 3.1 below shows the subrack layout of the SMA1/4 Ultra Compact.The equipment can be seen as a set of component parts that are present in all configurations(the Core), plus other cards that are required in varying quantities depending on application.S3_01S3_02 S3_03 S3_04S3_05Generic Tributary 1Generic Tributary 2Line Slot 1Protection Core CardGen Trib LTU 1Line Slot 1Core/CCU CardCore Trib B (Protection)Core Trib ACOMMS/AUX/AncillaryLine Slot 2Line Slot 2Gen Trib LTU 2Core Trib LTU 1Core Trib LTU 2PWR/LCT LTU1S1_01S1_02S1_03S1_04S1_05S1_06S1_07Fan Tray UnitFigure 3.1 – UC Subrack Layout1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 301Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT3.1 EQUIPING/CONFIGURATION RULESIn order to realise a particular customer selected configuration the steps set out below should befollowed.Shelf Configuration/Equipping StepNotes1 Select the Core (m<strong>and</strong>atory) See section 5.12 Select the Power LTU (9 pin or 3 pin - m<strong>and</strong>atory)(from Q1 2006 with SP03AC & SP13AC UC Cores)See sections 5.2.2.1 &5.2.2.23 Select forced cooling if required. See section 5.2.1.34 Select Core Protection if required (also needed if 2M Prot See section 5.2.1is to be selected)5 Select line modules required for use on Core <strong>and</strong> See section 5.3Protection units.6 Select 2M Core Trib Option if required. See section 5.4.17 Select 2M Core LTU options See section 5.4.1.28 Select 2M Core Trib protection if required. (also needed if See section 5.4.1.3Core Protection is to be selected)9 Select type of Generic trib required in slot 1 See section 5.510 Select required Generic Tributary slot 1 LTUSee section 5.5Note: LTU required to power Trib Card – select SP70D if noLTU traffic access required.11 Select type of Generic trib required in slot 2 See section 5.512 Select required Generic Tributary slot 2 LTUSee section 5.5Note: LTU required to power Trib Card – select SP70D if no LTUtraffic access required.13 Select Comms/AUX/Ancillary Card if required See section 5.614 Select required EMC covers See section 5.715 Select required backup <strong>and</strong> LCT S/W if required. See section 5.816 Select miscellaneous <strong>and</strong> kits of parts if required. See section 5.93.1.1 Configurable card options for each card slot – SMA-1/4UCPlease refer to Figure 3.1 <strong>and</strong> see section 5 for details.Notes:-1) Options of do not fit are also possible. An EMC cover then covers the spare slot.2) The assemblies fitted into the Core Trib LTU slots are actually a composite of two items. One itemis an extender card <strong>and</strong> one is a front panel card. These two items are fitted together duringinstallation before pushing the entire assembly into the appropriate slot.Slot Slot Name Card Options Card Code CommentsS1_01 Generic Trib 1 Various Various See Section 5.5S1_02 Generic Trib 2 Various Various See Section 5.5S1_03 Protection Core Card Protection Core Card orCore/CCU Card1HAT61114AAT1HAT61105AAFS1_04 Core/CCU Card Core/CCU Card 1HAT61105AAFS1_05 Core Trib BCore Trib Card (64x2M) 1HAT61107AAK(Protection)-CCU function is disabledin this slot1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 302Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTS1_06 Core Trib A Core Trib Card (64x2M) 1HAT61107AAKS1_07 Comms/Aux/Ancillary Comms/Aux/Ancillary 1HAT61106BAE (1)S3_01 Gen Trib LTU 1 3x34/45M LTU orGeneric Trib Pwr LTUV1 or Generic Trib PwrLTU V2 or140/155M LTUS3_02 Gen Trib LTU 2 3x34/45M LTU orGeneric Trib Pwr LTUV1 or Generic Trib PwrLTU V2 or140/155M LTUS3_03 Core Trib LTU 1 Core Trib (32x2) LTU(UNBAL)orCore Trib (32x2) LTU(BAL)S3_04 Core Trib LTU 2 Core Trib (32x2) LTU(UNBAL)or1HAM61215AAH1HAM61218AAM1HAM61232AAE1HAM61228AAC1HAM61215AAH1HAM61218AAM1HAM61232AAE1HAM61228AAC1HBA60827AAV +1HBA60828AAX1HBA60831AAX +1HBA60832AAA1HBA60827AAV +1HBA60828AAXSee note aboveSee note above1HBA60831AAX +Core Trib (32x2) LTU 1HBA60832AAA(BAL)S3_05 Power/LCT LTU Power/LCT LTU 1HAM61217AAK or 9 pin D connector1HAM61217ABC 3 pin Power D connectorS0_01 Fan Tray Unit SMA1/4UC Fan Tray 1HAM61219AAP Only if required- see Section 5.2.1.3LineSlotsLine Slot Line Modules See section 4.4.1(1)1HAT61106AAH superseded by Enhanced Comms/Aux/Ancillary Card. See section 10.1 for details3.2 SALEABLE ENITITIESThe items within the Product Structure are sold as Saleable Entities (SEs)Every SE has a set of dates associated with it, each of which marks a key event during itslifecycle: -Release of Information DateAcceptance of Orders DateFirst Time Off DateVolume Shipment DateLast Time Buy DateWithdrawn DateThese dates are the responsibility of Business Support to define, review <strong>and</strong> set within IPS.They are in addition to, <strong>and</strong> differ from, Effectivity Dates, which assign a SE to Product codes.1ADR60773AAC-CQA (see reference 0.5.15) is the authoritative guide for Saleable Entitystructures on this product.End of section1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 303Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT4 EX PRODUCT STRUCTUREFigure 4.1 below shows the subrack layout of the SMA Extended Ultra Compact.The equipment can be seen as a set of component parts that are present in all configurations(the Core), plus other cards that are required in varying quantities depending on application.S3 01 2M LTU 1AS3 02 2M LTU 1BS3 03 2M LTU 1CS3_04 Generic Trib 1 PSU/LTUS3 05 2M LTU 1AS3 06 2M LTU 1BS3 07 2M LTU 1CS3_08 Generic Trib 2 PSU/LTUS3 09 2M LTU 1AS3 10 2M LTU 1BS3 11 2M LTU 1CS3_12 Generic Trib 3 PSU/LTUS3 13 2M LTU 1AS3 14 2M LTU 1BS3 15 2M LTU 1CS3_16 Generic Trib 4 PSU/LTUS3_17 Generic Trib 5 PSU/LTUS3_18 Generic Trib 6 PSU/LTUS3_19 Generic Trib 7 PSU/LTUS3_20 Power & LCT LTUS3_21 Power & LCT LTUTribGroup1S1_01 2M Trib 1S1_02 Generic Trib 1TribGroup2S1_03 2M Trib 2S1_04 Generic Trib 2S1_05 2M Protection TribS1_06 Traffic Core BS1_07 Traffic Core A / CCU[blank]TribGroup3S1_08 2M Trib 3S1_09 Generic Trib 3TribGroup4S1_10 2M Trib 4S1_11 Generic Trib 4S1_12 Generic Trib 5S1_13 Generic Trib 6S1_14 Generic Trib 7S1_15 Comms/Aux/Ancillary UnitS0_01 Fan Unit S0_02 Fan UnitFigure 4.1 –EX Subrack Layout4.1 EQUIPING/CONFIGURATION RULESIn order to realise a particular customer selected configuration the steps set out below should befollowed.1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 401Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT4.1.2 EX Trib GroupsDue to the number of backplane interfaces on the 63x2Mbit/s Trib card, it is not possible to fitit into a Generic trib slot. EX therefore uses dedicated 2M Trib slots that are each associatedwith a Generic Trib slot. This pair of Trib slots is known as a Trib group as shown in Figure 4.1The two Trib slots in a Trib Group share the same b<strong>and</strong>width to the Switch <strong>and</strong> are thereforemutually exclusive. For example, if a Generic Trib is fitted in Generic Trib Slot 1 (S1_02) thena 2M Trib cannot be fitted in 2M Trib Slot 1 (S1_01). Likewise, if a 2M Trib is fitted in 2MTrib Slot 2 (S1_03) then a Generic Trib cannot be fitted in Generic Trib Slot 2 (S1_04) <strong>and</strong> soon. This only applies to the first 4 pairs of Trib slots, as Generic Tribs 5, 6 <strong>and</strong> 7 do not have2M Tribs associated with them.4.1.3 EX B<strong>and</strong>width DistributionThere is a finite amount of b<strong>and</strong>width between the Switch <strong>and</strong> the Trib slots <strong>and</strong> therefore thereare restrictions on how this b<strong>and</strong>width is distributed within the EX backplane. Figure 4.2 <strong>and</strong>Figure 4.3 show how the b<strong>and</strong>width is distributed:STM1/4 CoreSTM1/4SFPLine I/FSTM1/4SFPLine I/F44VC 4/3/12 switch44STM1/4SFPLine I/FSTM1/4SFPLine I/F63x2MbTrib2 2 2 4 2GenericTrib63x2MbTribGenericTrib63x2MbTribGenericTrib63x2MbTribGenericTrib63x2MbProt Trib4GenericTribTo Lineinterfaceson partnercore cardSTM-1EquivalentsLTULTUTribGroup 1LTULTUTribGroup 2LTULTUTribGroup 3LTULTUTribGroup 42MbprotbusLTUTrib 5NOTE The use of the 2Mb card or the Generic tribis mutually exclusive per trib groupFigure 4.2 – SMA1/4EX Switch B<strong>and</strong>width Distribution1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 404Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTAs shown in Figure 4.2, Trib Groups 1 to 3 have an equivalent of 2xSTM-1 b<strong>and</strong>width <strong>and</strong>Tribs 4 to 5 have an equivalent of 4xSTM-1. Trib slots 6 & 7 have no connection to the switchwhen a SMA1/4 Core is fitted <strong>and</strong> therefore cannot be used.STM16 CoreSTM1/4SFPLine I/FSTM1/4SFPLine I/F44VC 4/3/1 switch44STM1/4SFPLine I/FSTM1/4SFPLine I/F63x2MbTrib2 2 2 4 2GenericTrib63x2MbTribGenericTrib63x2MbTribGenericTrib63x2MbTribGenericTrib63x2MbProt Trib4GenericTrib4GenericTrib4GenericTribTo Lineinterfaceson partnercore cardSTM-1EquivalentsLTULTUTribGroup 1LTULTUTribGroup 2LTULTUTribGroup 3LTULTUTribGroup 42MbprotbusLTUTrib 5LTU LTUTrib 6 Trib 7NOTE The use of the 2Mb card or theGeneric trib is mutually exclusive perFigure 4.3 – SMA16EX Switch B<strong>and</strong>width DistributionFigure 4.3 shows, that when an SMA16 Core is fitted, Trib Groups 1 to 3 have an equivalent of2xSTM-1 b<strong>and</strong>width <strong>and</strong> Tribs 4 to 7 has an equivalent of 4xSTM-1.4.1.4 EX Overhead DistributionWhen using an SMA1/4 Core card the OH access to Tributary slots is limited. The followingtable shows the number of DCCr <strong>and</strong> DCCm channels available to each Trib slot:TribNumberSlotNumberB<strong>and</strong>width toSwitch (STM1Equiv.)SMA1/4 Core SMA16 CoreDCCr DCCm DCCr DCCm1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 405Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT1 S1_02 2 - - 2 22 S1_04 2 - - 2 23 S1_09 2 - - 2 24 S1_11 4 2 2 2 25 S1_12 4 2 2 2 26 S1_13 4 n/a n/a 2 27 S1_14 4 n/a n/a 2 2Note: If a Trib card is fitted with less than or equal to 2 SDH interfaces a DCCr <strong>and</strong> a DCCmwill be associated with each interface. If the Trib card has more than 2 SDH interfaces a DCCrwill be associated with the first interface, a DCCr with the second, a DCCm with the third <strong>and</strong>finally a DCCm with the fourth.4.1.5 Trib / LTU Slot AssociationThe following table shows which Trib Slots are connected to which LTU slots via the backplane:Trib DescriptionTrib SlotNumberLTU DescriptionLTU SlotNumber2M Trib 1 (ports 1-21) S1_01 2M LTU 1A S3_012M Trib 1 (ports 22-42) S1_01 2M LTU 1B S3_022M Trib 1 (ports 43-63) S1_01 2M LTU 1C S3_03Generic Trib 1 S1_02 Generic Trib 1 PSU/LTU S3_042M Trib 2 (ports 1-21) S1_03 2M LTU 2A S3_052M Trib 2 (ports 22-42) S1_03 2M LTU 2B S3_062M Trib 2 (ports 43-63) S1_03 2M LTU 2C S3_07Generic Trib 2 S1_04 Generic Trib 2 PSU/LTU S3_082M Protection Trib S1_05 --- ---Traffic Core B S1_06 --- ---Traffic Core A / CCU S1_07 --- ---2M Trib 3 (ports 1-21) S1_08 2M LTU 3A S3_092M Trib 3 (ports 22-42) S1_08 2M LTU 3B S3_102M Trib 3 (ports 43-63) S1_08 2M LTU 3C S3_11Generic Trib 3 S1_09 Generic Trib 3 PSU/LTU S3_122M Trib 4 (ports 1-21) S1_10 2M LTU 4A S3_132M Trib 4 (ports 22-42) S1_10 2M LTU 4B S3_142M Trib 4 (ports 43-63) S1_10 2M LTU 4C S3_15Generic Trib 4 S1_11 Generic Trib 4 PSU/LTU S3_16Generic Trib 5 S1_12 Generic Trib 5 PSU/LTU S3_17Generic Trib 6 S1_13 Generic Trib 6 PSU/LTU S3_18Generic Trib 7 S1_14 Generic Trib 7 PSU/LTU S3_19Comms/Aux/Ancillary Unit S1_15 --- ------ --- Protection Power LTU S3_20--- --- Power & LCT LTU S3_211ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 406Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT4.1.6 EX Power DistributionThe 2M Tribs, Traffic Cores <strong>and</strong> Comms/Aux/Ancillary Unit have on card 50v converters. Theare fed directly from the Power Feed LTUs via the backplane.Generic Tribs do not have on card 50v converters <strong>and</strong> therefore need a Generic Trib PowerLTU (see section 5.5.1).The EX products have duplicated Power Feed LTUs (slots S3_20 & S3_21). The Power &LCT LTU (S3_21) is part of the product’s Core SE (i.e. SP20A & SP30A). The ProtectionPower LTU (S3_20) is available as an option <strong>and</strong> is required if a duplicated power feed is to beused.4.2 SALEABLE ENITITIESThe items within the Product Structure are sold as Saleable Entities (SEs)Every SE has a set of dates associated with it, each of which marks a key event during itslifecycle: -Release of Information DateAcceptance of Orders DateFirst Time Off DateVolume Shipment DateLast Time Buy DateWithdrawn DateThese dates are the responsibility of Business Support to define, review <strong>and</strong> set within IPS.They are in addition to, <strong>and</strong> differ from, Effectivity Dates, which assign a SE to Product codes.1ADR60773AAC-CQA (see reference 0.5.15) is the authoritative guide for Saleable Entitystructures on this product.End of section1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 407Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT5 SMA ULTRA COMPACT AND EXTENDED ULTRA COMPACT (UC& EX) SALEABLE ENTITIESReference 0.5.15 is the authority on which SEs are currently supported on the UC. However,the following list is accurate at time of publication of this CTA.Important note:- Where the SMA UC & EX product structure or Saleable Entityphilosophy differs significantly to previous Marconi products <strong>and</strong> CTA documents then itis listed here for reference.1) Tributary card Saleable Entities on previous products often came with connectors. OnSMA1/4UC the SEs do not contain connectors <strong>and</strong> they must be ordered separately. Anextensive range of connector kits of parts <strong>and</strong> pre-made cable assemblies are available toprovide these requirements. See section 14.2) Each separate release of software (e.g. R3.1, R3.2 R3.3.1 etc.) will have its own uniqueelement software build (ie that stored on the CF System memory card) <strong>and</strong> also LCT. It isessential for reasons of compatibility that corresponding LCT <strong>and</strong> Element software buildsmust be used. For example R3.2 Element Software must be used with R3.2 LCT etc.5.1 CORE SYSTEMAny configuration of the product requires a minimum set of items. For convenience these aregrouped together as a ‘Core’.The SMA UC & EX family consists of four separate products – SMA1/4UC, SMA1/4EX,SMA16UC & SMA16EX. There are currently 5 core options available for UC & EX, one foreach product <strong>and</strong> an additional one for SMA1/4UC with an unprotected 2M trib interface. Eachcore provides the minimum configuration for the product as shown below:Core SE Code Subrack Core/CCU Card NotesSP03AB UC STM1/4 SMA1/4UC – Min configuration. No traffic I/Fs &no software (See Note: 2, 3)SP03AC(from Q1 2006)UC STM1/4 SMA1/4UC – Min configuration. No traffic I/Fs,no PWR/LCT LTU & no software (See Note: 2, 3)SP03A-1 UC STM1/4 Withdrawn (See Note: 1)SP13AB UC STM4/16 SMA16UC – Min configuration. No traffic I/Fs,no Fans & no software (See Note: 2, 3, 4)SP13AC(from Q1 2006)UC STM4/16 SMA16UC – Min configuration. No traffic I/Fs,no Fans, no PWR/LCT LTU & no software (SeeNote: 2, 3, 4)SP20A EX STM1/4 SMA1/4EX – Min configuration. No traffic I/Fs &no software (See Note: 5)SP30A EX STM4/16 SMA16EX – Min configuration. No traffic I/Fs,no Fans & no software (See Note: 4, 5)Notes: 1. SP03A-1 has been withdrawn.2. SP03AB & SP13AB supersede SP03 & SP13 respectively. These new SEs do notinclude system software on CF card <strong>and</strong> one must now be ordered separately for eachCore UC system. Refer to section 5.8 for details.1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 501Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT3. From Q1 2006 SP03AC & SP13AC will supersede SP03AB & SP13AB respectively.These new core SEs will not include a Power/LCT LTU allowing introduction of the 3pin version. A Product Bulletin will be issued confirming the availability dates. Fromthis date a Power/LCT LTU must be ordered separately with each SP03AC or SP13ACCore UC system. Refer to section 5.2.2.1 <strong>and</strong> 5.2.2.2 for Power/LCT LTU details.4. SP13AB & SP30A no longer include a Fan tray by default. If a Fan tray is requiredthen one should be ordered separately. Refer to section 5.2.1.3 for details.5. SP20A & SP30A also do not include system software on CF card <strong>and</strong> one must beordered separately for each Core EX system. Refer to section 5.8 for details.5.1.1 SMA1/4UC Core (No Software) SP03ABSMA1/4UC Subrack 1HAG60627AAV X1CORE/CCU Card 1HAT61105AAF X1PWR/LCT LTU (9 pin) 1HAM61217AAK X1KOP- Subrack Mounting (ETSI&19”) 1MBB61388AAH X1Notes: 1. This SE supersedes SP03A <strong>and</strong> does not include system software on CF card. ACompact Flash software SE must now be ordered separately. Please refer to Section 5.8for details.2. The vertical mounting kit of parts (KOP) also contains an EMC Cover1MBA62266AAA for the fan tray slot. The EMC Cover should be fitted if no fan trayis configured. This KOP allows mounting either horizontally or vertically in st<strong>and</strong>ard19” telecom <strong>and</strong> ETSI racks. DIN 19” mounting is also possible –see section 5.9.5.1.2 SMA1/4UC Core (No Software, no Power/LCT LTU) SP03ACSMA1/4UC Subrack 1HAG60627AAV X1CORE/CCU Card 1HAT61105AAF X1KOP- Subrack Mounting (ETSI&19”) 1MBB61388AAH X1Notes: 1. From Q1 2006 SP03AC will supersede SP03AB. This new core SE will not include aPower/LCT LTU allowing introduction of the 3 pin version. A Product Bulletin will beissued confirming the availability dates. From this date a Power/LCT LTU must beordered separately with each SP03AC Core UC system. Refer to sections 5.2.2.1 <strong>and</strong>5.2.2.2 for Power/LCT LTU details.2. This SE does not include system software on CF card. A Compact Flash software SEmust be ordered separately. Please refer to Section 5.8 for details.3. The vertical mounting kit of parts (KOP) also contains an EMC Cover1MBA62266AAA for the fan tray slot. The EMC Cover should be fitted if no fan trayis configured. This KOP allows mounting either horizontally or vertically in st<strong>and</strong>ard19” telecom <strong>and</strong> ETSI racks. DIN 19” mounting is also possible –see section 5.9.5.1.3 SMA1/4UC 64x2Mbit/s Core Unprotected SP03A-1SE Withdrawn.1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 502Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT5.1.4 SMA16UC Core (No Software) SP13ABSMA1/4UC Subrack 1HAG60627AAV X1STM-4/16 Core A / CCU Card 03HAT00041AAQ X1PWR/LCT LTU (9 pin) 1HAM61217AAK X1KOP- Subrack Mounting (ETSI&19”) 1MBB61388AAH X1Notes: 1. This SE supersedes SP13A <strong>and</strong> does not include system software on CF card. ACompact Flash software SE must now be ordered separately. Please refer to Section 5.8for details.2. The vertical mounting kit of parts (KOP) also contains an EMC Cover1MBA62266AAA for the fan tray slot. The EMC Cover should be fitted if no fan trayis configured. This KOP allows mounting either horizontally or vertically in st<strong>and</strong>ard19” telecom <strong>and</strong> ETSI racks. DIN 19” mounting is also possible –see section 5.9.5.1.5 SMA16UC Core (No Software, no Power/LCT LTU) SP13ACSMA1/4UC Subrack 1HAG60627AAV X1STM-4/16 Core A / CCU Card 03HAT00041AAQ X1KOP- Subrack Mounting (ETSI&19”) 1MBB61388AAH X1Notes: 1. From Q1 2006 SP13AC will supersede SP13AB. This new core SE will not include aPower/LCT LTU allowing introduction of the 3 pin version. A Product Bulletin will beissued confirming the availability dates. From this date a Power/LCT LTU must beordered separately with each SP13AC Core UC system. Refer to sections 5.2.2.1 <strong>and</strong>5.2.2.2 for Power/LCT LTU details.2. This SE does not include system software on CF card. A Compact Flash software SEmust now be ordered separately. Please refer to Section 5.8 for details.3. The vertical mounting kit of parts (KOP) also contains an EMC Cover1MBA62266AAA for the fan tray slot. The EMC Cover should be fitted if no fan trayis configured. This KOP allows mounting either horizontally or vertically in st<strong>and</strong>ard19” telecom <strong>and</strong> ETSI racks. DIN 19” mounting is also possible –see section 5.9.5.1.6 SMA1/4EX Core SP20ASMA EX Subrack 03HAG00001AAX X1STM-1/4 Core / CCU Card 1HAT61105AAF X1EX Power/LCT LTU 03HAM00008AAX X1Fan EMC Blanking Cover 03MBB00017AAT X2Notes: 1. This SE does not include system software on CF card. A Compact Flash software SEmust now be ordered separately. Please refer to Section 5.8 for details.2. The subrack comes complete with integral mounting brackets to suit 300mm <strong>and</strong>600mm deep ETSI racks (a separate mounting bracket is available for 19” wide racks) –see section 5.95.1.7 SMA16EX Core SP30ASMA EX Subrack 03HAG00001AAX X1STM-4/16 Core A / CCU Card 03HAT00041AAQ X1EX Power/LCT LTU 03HAM00008AAX X1Fan EMC Blanking Cover 03MBB00017AAT X21ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 503Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTNotes: 1. This SE does not include system software on CF card. A Compact Flash software SEmust now be ordered separately. Please refer to Section 5.8 for details.2. The subrack comes complete with integral mounting brackets to suit 300mm <strong>and</strong>600mm deep ETSI racks (a separate mounting bracket is available for 19” wide racks) –see section 5.9.5.2 ITEMS ASSOCIATED WITH THE CORE5.2.1 Generic SEs used in both UC <strong>and</strong> EX5.2.1.1 SMA1/4UC & EX Protection ADM Unit SP71FThis unit provides protection of the STM1/4 Line/Switch core associated with SMA1/4UC <strong>and</strong>SMA1/4EX. It is fitted in the following slots depending on subrack type:UC Subrack: Slot S1_03EX Subrack: Slot S1_06In SMA1/4UC this unit also contains the traffic processor for its related 2M Core Trib.Therefore:-1) If 2M Core Protection (Section 5.4.1.3) is required then this Protection Core Card mustalso be fitted.2) If this Protection Core card is fitted <strong>and</strong> a 2M Core trib (Section 5.4.1.1) is alsoprovisioned then the 2M Core Protection Trib (Section 5.4.1.3) must also be fitted.5.2.1.2 SMA16UC & EX Core B ADM Unit SP71GThis unit provides a second STM-16 Line interface <strong>and</strong> protection of the Switch coreassociated with SMA16UC <strong>and</strong> SMA16EX. It is fitted in the following slots depending onsubrack type:UC Subrack: Slot S1_03EX Subrack: Slot S1_06In SMA16UC this unit also contains the traffic processor for its related 2M Core Trib.Therefore:-1) If 2M Core Protection (Section 5.4.1.3) is required then this Protection Core Card mustalso be fitted.2) If this Protection Core card is fitted <strong>and</strong> a 2M Core trib (Section 5.4.1.1) is alsoprovisioned then the 2M Core Protection Trib (Section 5.4.1.3) must also be fitted.5.2.1.3 SMA1/4/16UC & EX – Forced Air Cooling SP03BForced Air cooling is available for the SMA1/4/16UC <strong>and</strong> EX products using a slide in fantray. In order to give the operators benefits in power consumption <strong>and</strong> maintenance costs thefan tray should only be fitted if any of the following conditions apply.1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 504Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT1. An SMA1/4/16UC is mounted in a horizontal position OR2. The air intake of an SMA1/4/16UC or EX shelf is above 45degC OR3. A Layer 2 Card (ELS1000s, SP58A) is fitted, <strong>and</strong> the slot to it’s right is also occupied.Fan assembly 1HAM61219AAP X1Fan Filter 1MAA68476AAT X1The EX subrack can be fitted with two fan trays. Two should be fitted if case 2. above applies<strong>and</strong> in case 3. any Layer 2 card meeting the conditions described should have a fan tray below.5.2.2 UC Specific ItemsThe following SEs are specific to the UC products (i.e. SMA1/4UC & SMA16UC). They donot apply to the EX products.5.2.2.1 SMA1/4UC Power & LCT LTU (9 pin) SP03DBEvery SMA1/4UC Core must be fitted with a Power & LCT LTU. This was originally includedin the SMA1/4UC Core SEs, however from Q1 2006 (cutover date to be advised via ProductBulletin) one must be ordered separately.The two options offer power connectors using either 9 pin D-types (SP03DB) or 3 pin ‘Italtel’D Types (SP03DA).This SE contains one Power & LCT LTU with 9 pin D type connectors as originally offered.The LTU has two such connectors to support dual feeding. This LTU is fitted in slot S3_05.Power & LCT LTU (9 pin) 1HAM61217AAK X1Power cable SP03AA (1HAU62501AAF) can be used to connect this LTU to the top of rackpower distribution. This cable is 2.0m in length with an additional 0.4m breakout.5.2.2.2 SMA1/4UC Power & LCT LTU (3 pin) SP03DAThis SE contains one Power & LCT LTU with 3 pin ‘Italtel’ D type connectors. The LTU hastwo such power connectors to support dual feeding. This LTU is fitted in slot S3_05.Power & LCT LTU (3 pin) 1HAM61217ABC X1Power cable SP20AA (1HAU62025AAM) can be used to connect this LTU to the top of rackpower distribution. This cable is 2.0m in length with an additional 0.4m breakout.5.2.3 EX Specific Items5.2.3.1 EX Power Feed Protection LTU SP20DIf a protected DC power feed is required for an EX product, a second Power LTU must bepurchased.The protection power feed LTU is fitted in slot S3_20.1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 505Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTNote: This power LTU is identical to the one supplied in the Core however the LCT port willonly work on the LTU fitted in slot S3_21.5.3 SFP TRIB & LINE INTERFACESFor the UC & EX products, most of the SDH interfaces are realised in the form of a slide SmallForm-Factor Pluggable (SFP) module. The following table shows the SFP interface types thatare available <strong>and</strong> which cards they are compatible with. The number represents the maximumnumber of SFPs that can be fitted.SE Code I/F Type ConnectorTypeSMA1/4Core (1)SMA16Core (2)QuadFlex (3)SU65AA STM-1 Elec. 1.0/2.3 Coax 2 - 4SU66AA STM-1 S1.1 LC 2 - 4SU66AB STM-1 L1.1 LC 2 - 4SU66AC STM-1 L1.2 LC 2 - 4SU67AA STM-4 S/I4.1 LC 2 1 1SU67AB STM-4 L4.1 LC 2 1 1SU67AC STM-4 L4.2 LC 2 1 1SU67AD STM-4 L4.1+ LC 2 1 1SU67AE STM-4 L4.2+ LC 2 1 1SU68AB STM-16 S16.1 LC - 1 -SU68AC STM-16 L16.1 LC - 1 -SU68AD STM-16 L16.2 LC - 1 -(1) SMA1/4 Core: 1HAT61105AAF – STM1/4 Core/CCU1HAT61114AAT – STM1/4 Protection Core(2) SMA16 Core: 03HAT00041AAQ – STM16 Core A ADM Unit03HAT00041ABH – STM16 Core B ADM Unit(3) Quad Flex: 03HAT00043AAU – Quad Flexible STM1/STM4 SFP Trib5.4 2MBIT/S TRIBUTARY INTERFACES5.4.1 UC Specific 2Mbit/s Tributary5.4.1.1 UC 64 Port 2MBit/s Core Traffic Unit SP60CThis unit provides traffic processing for up to 64 2Mbit/s channels. In order to gain physicalaccess to the 2M interface an LTU must be fitted (see section 5.4.1.2).Note :-If Core Protection has been provisioned (Section 5.2.1.1 or 5.2.1.2) <strong>and</strong> this 2M CoreTrib is then selected then 2M Core Protection (Section 5.4.1.3) must also be provided.The unit should be pushed into slot S1_0664x2M Core Trib Card (V2) 1HAT61107ABC X11ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 506Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT5.4.1.2 UC 2Mbit/s LTU OptionsThe 2M Core tributary selected above offers the use of up to 64 2Mbit/s channels. Either 1 or 2LTU assemblies should be selected, each giving physical access to 32 of the possible 64channels.The LTU assembly is made up of two modules. During installation the two modules are fittedtogether before pushing the entire assembly into the relevant slot. The slots used are S3_03 <strong>and</strong>S3_04.The LTU is available in 2 different interface types. Balanced or Unbalanced may be selected.5.4.1.2.1 Core Trib 32x2Mbit/s LTU Unbalanced SP60CA32x2M Unbalanced LTU -Interface Module 1HBA60827AAV X132x2M Unbalanced LTU – Front Panel 1HBA60828AAX X15.4.1.2.2 Core Trib 32x2Mbit/s LTU Balanced SP60CB32x2M Balanced LTU -Interface Module 1HBA60831AAX X132x2M Balanced LTU – Front Panel 1HBA60832AAA X15.4.1.3 UC 64 Port 2MBit/s Core Protection Traffic Unit SP60CThis unit is used to supply 1:1 2M traffic processing protection. It is identical to the st<strong>and</strong>ard 64Port 2Mbit/s Core Traffic unit <strong>and</strong> hence the saleable entity number is identical.This option can only be chosen after both a 2M Core Trib has been fitted in the other Core Tribslot (see section 5.4.1.1) <strong>and</strong> a Protection ADM Unit (see section 5.2.1.1 or 5.2.1.2) has beenfitted.The unit should be pushed into slot S1_05.64x2M Core Trib Card (V2) 1HAT61107ABC X15.4.2 EX Specific 2Mbit/s Tributary5.4.2.1 EX 63 Port 2MBit/s Traffic Unit SP60EThis unit provides traffic processing for up to 63 2Mbit/s channels. In order to gain physicalaccess to the 2M interface an LTU must be fitted (see section 5.4.2.2).The 2M Trib unit can be fitted into any or all of the following slots: S1_01, S1_03, S1_08 <strong>and</strong>S1_10EX 63x2M Trib Card 02HAT00056AAQ X15.4.2.2 EX 2Mbit/s LTU OptionsThe EX 2M LTUs are available in two interface types. Balanced 120 ohm or Unbalanced 75ohm may be selected. For Balanced interfaces the maximum possible number of 2M ports is252. For Unbalanced interfaces this number is reduced to 126 due to the physical size of theLTU area.1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 507Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT5.4.2.2.1 EX 63x2Mbit/s LTU Unbalanced SP60EAThis LTU is a multi-card assembly with a large front-plate to give enough physical space forthe 126 1.0/2.3 coax connectors. When this LTU is fitted it covers a total of 7 slots (6x2M LTU+ 1xGeneric LTU). This makes the adjacent 2M Trib LTU area unusable. The following tableshows which combination of slots this LTU can be fitted into:2M LTU 1 2M LTU 2 2M LTU 3 2M LTU 4S3_01 S3_02 S3_03 S3_05 S3_06 S3_07 S3_09 S3_10 S3_11 S3_13 S3_14 S3_15EX 63x2M LTU – 2M Trib 1EX 63x2M LTU – 2M Trib 2EX 63x2M LTU – 2M Trib 3EX 63x2M LTU – 2M Trib 1 EX 63x2M LTU – 2M Trib 3As can be seen from the table, fitting 2M Trib 2 with an Unbalanced LTU will not allow <strong>and</strong>future expansion of 2M Unbalanced interfaces.EX 63x2M Unbalanced LTU 02HAM00003AAL X15.4.2.2.2 EX Vertically Extended 63x2Mbit/s LTU Unbalanced SP60EZThis is a variation on the st<strong>and</strong>ard 63x2Mbit/s LTU (SP60EA). It is used when more than 126 x2Mbit/s ports are required from a single EX product. This LTU should also be used if anyfuture expansion of the NE will increase the number of 2M ports beyond 126. The increase to amaximum of 252 x 2Mbit/s ports is achieved by vertically extending the LTU beyond the topof the subrack (see Figure 5.1). When planing installation it should be noted that this LTU willextend 180mm beyond the top of the subrack.EX 63x2M Vert Extended Unbal LTU 03HAM00009AAA X1Cage Assembly – Vert Extended LTU 03MBA00083AAE X11ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 508Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT180mmS1 01 2M Trib 1S1 02 Generic Trib 1S1 03 2M Trib 2S1 04 Generic Trib 2S1 05 2M Protection TribS1_06 Traffic Core BS1_07 Traffic Core A / CCUS1 08 2M Trib 3S1 09 Generic Trib 3S1 10 2M Trib 4S1 11 Generic Trib 4S1 12 Generic Trib 5S1 13 Generic Trib 6S1 14 Generic Trib 7S1_15 Comms/Aux/Ancillary UnitS3 01 2M LTU 1AS3 02 2M LTU 1BS3 03 2M LTU 1CS3_04 Generic Trib 1S3 05 2M LTU 1AS3 06 2M LTU 1BS3 07 2M LTU 1CS3_08 Generic Trib 2S3 09 2M LTU 1AS3 10 2M LTU 1BS3 11 2M LTU 1CS3_12 Generic Trib 3S3 13 2M LTU 1AS3 14 2M LTU 1BS3 15 2M LTU 1CS3_16 Generic Trib 4S3_17 Generic Trib 5S3_18 Generic Trib 6S3_19 Generic Trib 7S3 20 Power & LCTS3 21 Power & LCTS0 01 Fan Unit S0 02 Fan UnitFigure 5.1 – Vertically Extended 2Mbit/s Unbal LTUs5.4.2.2.3 EX 21x2Mbit/s LTU Balanced SP60EBThis is a single width LTU providing 21 ports of Balanced 2M on two 44-pin D-typeconnectors. Three of these LTUs are required to provide the full 63-ports of connectivity foreach 2M Trib card.This LTU can be fitted in the following slots:Trib 1: S3_01, S3_02 <strong>and</strong> S3_03Trib 2: S3_05, S3_06 <strong>and</strong> S3_07Trib 3: S3_09, S3_10 <strong>and</strong> S3_11Trib 4: S3_13, S3_14 <strong>and</strong> S3_15EX 21x2M Balanced LTU 02HAM00002AAJ X11ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 509Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT5.4.2.3 EX 63 Port 2MBit/s Core Protection Traffic Unit SP60EThis is the same unit/SE as the worker trib card. It has been highlighted to show an additionaltrib card is required for 1:N protection. If required this card is fitted in slot S1_05.EX 63x2M Core Trib Card 02HAT00056AAQ X15.5 GENERIC TRIBUTARY CARDSNot all legacy Generic Trib Cards in the SMA range are compatible with UC & EX thereforenew SE codes have been generated to identify which cards are available for use in UC & EX.5.5.1 Generic Tributary Power LTU SP70C/SP70DUC & EX products use a distributed power supply architecture, where the main 50V supply tothe subrack is fed to each of the cards <strong>and</strong> then converted on card to the voltage levels required.All UC & EX specific cards have been designed with on board PSUs however Generic TribCards can be from legacy products without the on board converter. To overcome this problem aGeneric Trib Power LTU has been designed, which has the 50V conversion on the LTU <strong>and</strong>feeds low voltage power to the Trib Card.If a Generic Tributary with front panel access is to be used, this SE must be ordered to supplypower to the associated tributary slot. If the tributary card has LTU access then the power forthe tributary will be supplied by the LTU contained within the LTU plug-up tributary SEThis unit can be used in the following slots:UC Subrack: S3_01 & S3_02EX Subrack: S3_04, S3_08, S3_12, S3_16, S3_17, S3_18 & S3_19SP70CGeneric Trib Power LTU 1HAM61218AAM X1Note:- A new higher power version of the Trib Power LTU is available. This is essential foruse when the Tributary card is either an ETO-100 or Layer 2 card. It will have the SaleableEntity designation SP70D <strong>and</strong> will supersede SP70C.SP70DGeneric Trib Power LTU 1HAM61232AAE X1SP70C is only compatible with SMA1/4UC. From UC & EX Release 3.3 onwards onlySP70D should be ordered.5.5.2 LTU Plug up Tributary CardsIf the tributary card to be used is LTU plug up then an UC & EX specific SE should be chosenwhich includes the tributary card <strong>and</strong> LTU specific to UC & EX.SE Code SE Description ME details ME Codes QtySP61AUC & EX 3 Port 34Mbit/s Trib+ LTU & Power ModuleSMA 34M Tributary Card (INTL)3x34/45M LTU1HAT60622BAN1HAM61215AAFX1X11ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 510Issue 7


SP63ASP62CDSP64CSP65TASMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTUC & EX 3 Port 45Mbit/s Trib+ LTU & Power ModuleUC & EX 34Mbit/s Transmux+ LTU & Power ModuleUC & EX 140 Trib Card+ LTU & Power ModuleUC & EX STM-1 TCM DualElec. + LTU & Power ModuleSMA 45M Tributary Card3x34/45M LTUSMA 34M Transmux Card3x34/45M LTUSMA 140M Tributary Card (1.0/2.3)140/155Mbit Electrical & PowerLTUSMA STM-1 TCM Dual ElectricalTributary Card (1.0/2.3)140/155Mbit Electrical & PowerLTU.1HAT60623BAQ1HAM61215AAF1HAT60979AAC1HAM61215AAF1HAT60624CAP (1)1HAM61228AAC1HAT61004ABP1HAM61228AACNotes:-1. 140M Tributary card 1HAT60624BFE has been superseded by 1HAT60624CAP due toobsolescence issues.X1X1X1X1X1X1X1X15.5.3 Front Plug up Tributary CardsA number of front plug up tributary cards are available. However, if this option is chosen thena Generic Tributary Power LTU SE must be fitted as detailed in section 5.5.1.5.5.3.1 UC & EX Multirate STM-1/STM-4 SFP Trib SP67EAThe Quad STM-1/STM-4 Trib SP67EA uses SFP type modules to provide the STM electricalor optical interfaces. See Section 5.3 for the types of SFPs available. The following table showsthe number of SFPs that can be fitted depending on which Trib slot the Quad card is fitted in:Subrack Slot STM-1SFPSTM-4SFPUC S1_01 4 1UC S1_02 4 1EX S1_02 2 0EX S1_04 2 0EX S1_09 2 0EX S1_11 4 1EX S1_12 4 1EX * S1_13 4 1EX * S1_14 4 1* Only available with STM-16 Core ADM Unit fittedUC & EX Quad STM-1/STM-4 SFP Trib 03HAT00043AAU X15.5.3.1.1 Multirate Trib Communication Channels MappingThe following section details the communications channel mapping on the Multirate Trib.Limitations to the comms channels exist because the Multirate can be used as a 4 port card butthe internal architecture of UC & EX only gives access to 2 overhead busses for each trib slot.The configurable mapping of this card is described below in the following 4 diagrams:1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 511Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTSTREAM 1 DCCrDCCm1STREAM 2 DCCrDCCm1DCCrDCCmOH 1STREAM 3 DCCrDCCm1DCCrDCCmOH 2STREAM 4 DCCrDCCm1DCC mapping between optical ports <strong>and</strong> Backplane OH Bus for Quad STM-1STREAM 1 DCCrDCCmSTREAM 2 DCCrDCCmDCCrDCCmOH 1STREAM 3 DCCrDCCm11DCCrDCCmOH 2STREAM 4 DCCrDCCm11DCC mapping between optical ports <strong>and</strong> Backplane OH Bus for Dual STM-1 <strong>and</strong> STM-4STREAM 1F2 #1F3 #11STREAM 2F2 #1F3 #11F2 #1F3 #1OH 1STREAM 3F2 #1F3 #11F2 #1F3 #1OH 2STREAM 4F2 #1F3 #11F2 mapping between optical ports <strong>and</strong> Backplane OH Bus for all modes *** SW only allowsaccess to 2 channel ***AUX SEL2STREAM 1 AUXAUX SEL1AUXSTREAM 2 AUXAUX OH 2OH 1STREAM 3 AUXSTREAM 4 AUXAUX mapping between optical ports <strong>and</strong> Backplane OH Bus for all modes (Quad STM-1, DualSTM-1 <strong>and</strong> STM-4Figure 5.2 – Multirate Comms Channel mappings1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 512Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT5.5.3.2 Generic SMA CodesUC & EX support the following Series 3 <strong>and</strong> Series 4 Generic Tributary Cards but they are notdesignated as part of the UC & EX family:PacketspanSE Code SE DescriptionSP56A Packetspan ETA-100 8 x 10/100M RJ45 Ethernet Trib CardSP56B Packetspan ETO-100 8 x 10/100M Optical/Electrical Ethernet SFP Trib CardRefer to Packetspan CTA document 03ADR00001AAF-CTA for full Packetspan productdetails.Layer 2SE CodeSP58ASE DescriptionELS1000S Ethernet Line/LAN SwitchRefer to Layer 2 ELS1000S CTA document 05ABA00001AAL-CTA for full Layer 2 productdetails.SDH Line cardsThe Generic Tributary Cards shown in the following table are NOT compatible with the fullUC & EX product range. They will however work in the SMA1/4UC.These cards are being superseded by SP67EA <strong>and</strong> should not be ordered unlessabsolutely necessary.SE Code SE DescriptionSN65TA STM-1 TCM Electrical Mux Front AccessSN65TG STM-1 TCM Quad Electrical Mux Front AccessSN66TR,TS,TT STM-1 TCM Quad Opt Mux - S1.1, L1.1, L1.2SP66CA Dual STM-1 Optical Base CardModules for use with SP66CASP66EA STM-1 OPT DFW SC 1300NM S1.1SP66EC STM-1 OPT DFW SC 1300NM L1.1SP73A Blanking Module Cover5.5.3.3 Withdrawn CodesThe following unit, although in theory compatible with the UC & EX products, will not to beadvertised. It is still available for sale, but is effectively withdrawn on this particular productrange.SE CodeSP67TLSE DescriptionVC-4-4cv S4.1 SC Optical UnitThe following units are ONLY compatible with SMA1/4UC. They are still available for sale,but are effectively withdrawn on this particular product range.1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 513Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTSE Code SE DescriptionSB33B PACKETSPAN ERA-100 LINK ACCESS 100 FOR SMASN44AA 1310/1550NM RUGGEDISED COUPLER KITSN44AC 1536NM CONTRA RUGGEDISED COUPLER KITSN44AE 1554NM CONTRA RUGGEDISED COUPLER KITSN44AG 1536/1554NM CO-DIR TX RUGGEDISED COUPLER KITSN44AH 1536/1554NM CO-DIR RX RUGGEDISED COUPLER KITSN64CE 140M TRIB CARD FRNT ACES NB/HB TRIBSN66TG STM-1 TCM OPT MUX 1300NM L1.1 FCPC/SC (1.2E/S3)SN66TJ STM-1 TCM OPT MUX 1550NM L1.2 FCPC/SC (1.2E/S3)SN66TQ STM-1 TCM QUAD OPT MUX I1.1 FCPC/SC (SMA16)SP65TE STM-1 TCM DUAL ELEC MUX FRONT ACCESS SMA1/4C/4SP66AE STM-1 MOD - DFW FC OR SC 1550NM L1.2SP67TA STM-4 S3/S4 S4.1 SC/FC OPTICAL TRIBUTARY CARDSP67TB STM-4 S3/S4 L4.1 SC/FC OPTICAL UNITSP67TC STM-4 S3/S4 L4.1+ SC/FC OPTICAL UNITSP67TD STM-4 S3/S4 L4.2 SC/FC OPTICAL UNITSP67TE STM-4 S3/S4 L4.2+ SC/FC OPTICAL UNIT5.6 COMMS/AUX/ANCILLARY CARD SP53BThis unit is compatible with all UC & EX products. It provides access to a number of functionsvia its front panel connectors:-Aux1, Aux2, 2 x Sync in (T3), 2 x Sync out (T4)Ethernet/Q X (10/100M Network Management Interface),User inputs, user outputs,Station alarm scheme2M Test BusIf access to these functions is required then the unit should be fitted.This unit can be used in the following slots:UC Subrack: S3_07EX Subrack: S3_15Comms/Aux/Ancillary Unit 1HAT61106BAE (1) X1(1)1HAT61106AAH superseded by Enhanced Comms/Aux/Ancillary Card. See section 10.1 for details5.7 EMC COVERSA SMA subrack must have all slot positions filled to maintain the EMC performance ofthe equipment.After following the configuration procedure set out in section 3.1 or 4.1, all slots that do nothave a unit fitted must be equipped with an EMC cover. The covers available are listed in thetable below. The table also indicated which EMC covers are applicable to each subrack type(i.e. UC <strong>and</strong> EX)1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 514Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTSE Code SE Description UC EX ME Code QtySP73B EMC Cover Core Yes Yes 1MBA62249AAB X1SP73C EMC Cover Comms/Aux/Ancillary Yes Yes 1MBA62250AAW X1SP73EB EMC Cover UC & EX 2M Trib Yes Yes 1MBA62253AAD X1SP73DB EMC Cover UC 2M LTU Yes No 1MBA62252AAB X1SP73EA EMC Cover Generic Trib Yes Yes 1MBA61103ABS X1SP73DA EMC Cover Generic LTU Yes Yes 1MBA62251AAY X1SP73G EMC Cover EX 2M LTU Single No Yes 03MBA00068AAK X1SP73H EMC Cover EX 2M LTU Triple No Yes 03MBA00069AAM X1EX 2M LTU EMC covers are available in two sizes – single width <strong>and</strong> triple width. The singlewidth covers one 2M LTU slot (e.g. S3_01) <strong>and</strong> the triple covers three (e.g. S3_01, S3_02 <strong>and</strong>S3_03). The singles have been designed to be used when a 2M Trib is partially equipped with21x2M Balanced LTUs <strong>and</strong> the triples are for when no 2M Trib has been fitted.5.8 BACKUP AND LCT S/W.SP03SA SMA1/4UC Rel 3.1 Compact Flash 1HGC61024AAA X1SP03SC SMA1/4UC Rel 3.2 Compact Flash 1HGC61033AAN X1SP03SD SMA UC & EX Rel 3.3.1 Compact Flash 03HGC00032AAA X1SP03SE SMA UC & EX Rel 3.3.2 Compact Flash 03HGC00033AAC X1SP03SF SMA UC & EX Rel 3.4 Compact Flash 03HGC00037AAL X1SP81C SMA UC REL 3.1 Backup & LCT Software CD-ROM 1PHS60155AAA X1SP81CA SMA UC REL 3.2 Backup & LCT Software CD-ROM 1PHS60205AAF X1SP81CB SMA UC & EX REL3.3.1 Backup & LCT Software CD-ROM 03PHS00038AAE X1SP81CB (2) SMA UC & EX REL3.3.2 Backup & LCT Software CD-ROM 03PHS00039AAG X1SP81CF SMA UC & EX REL3.4 Rev2 Backup & LCT Software CD-ROM 03PHS00044AAL X1Note:-(1) The Compact flash memory device is no longer supplied as part of any Core SE.(2) R3.3.2 CD-ROM will also contain R3.3.1 software therefore SE stays the same.(3) Rel 3.3.2 & Rel 3.4 also support SMA16UC <strong>and</strong> SMA16EX products.5.9 MISCELLANEOUSA number of additional items are available which are listed below.SE Code SE Description ME Details QtySP82SA SMA UC & EX Product R3.1 Manuals on CD-ROM 1PHA60140AAH X1SP82SB SMA UC & EX Product R3.2 Manuals on CD-ROM 03PHA00003AAG X1SP82SC SMA UC & EX Product R3.3 Manuals on CD-ROM 03PHA00013AAW X1SP82SF SMA UC & EX Product R3.4 Manuals on CD-ROM 03PHA00015AAB X1SP83C UC & EX Software Licence 1SAA61558AAJ X1SM53A EOW H<strong>and</strong>set 1HFA20002AAJ X1SV30J RJ45 Local Craft Terminal Cable 1HAU61913ABX X1NH40H External USB Card Reader for use with LCT TBC X1NH40J Next Generation LCT with Windows 2000 + Card Reader 1HGA60654AAQ X1NH40K Next Generation LCT with Windows XP + Card Reader 1HGA60655AAS X1SP03C UC Special DIN 19” rack mounting K.O.Ps (UC Subrack) 1MBB61388BAE X1SP20C EX Special DIN 19” rack mounting K.O.Ps (EX Subrack) 03MBB00014AAM X11ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 515Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTMP93AA 34/45/140/STM1 1.0/2.3 ST214 1 Port Straight1MBB60851AAJ X1ConnectorsMP93AB 34/45/140/STM1 1.0/2.3 HFE2290 1 Port Straight 1MBB60891AAU X1ConnectorsMP93AC 34/45/140/STM1 1.0/2.3 BT2003 1 Port Straight1MBB60912AAG X1ConnectorsMP93AD 34/45/140/STM1 1.0/2.3 BT2003 1 Port Straight1MBB60912BAD X1Connectors T54MP93BA 2MBIT/S UNBAL ST212 1.0/2.3 16 Ports Straight1MBB60850AAG X2ConnectorsMP93BB 2MBIT/S UNBAL HFE2290 1.0/2.3 16 Ports Straight 1MBB60891ABM X2ConnectorsMP93BC 2MBIT/S UNBAL BT3002 1.0/2.3 16 Ports Straight 1MBB60913ABB X2ConnectorsMP93BD 2MBIT/S UNBAL BT3002 T54 1.0/2.3 16 Ports Straight 1MBB60913BBX X2ConnectorsMP93CC UC 2MBIT/S BAL D-TYPE KOP 32 Ports Connectors 1MBB61426AAT X1MP93CC03 UC 2MBIT/S BAL 2x 3M CABLE ASS 78W - OPEN END 1HAU62508AAV X132PTMP93CC20 UC 2MBIT/S BAL 2x 20M CABLE ASS 78W - OPEN END 1HAU62508ABN X132PTNew SE EX 2MBIT/S BAL D-TYPE KOP 21 Ports Connectors TBC X2SP52A Rack Mounted EOW Unit 1HAL60518AAY X1SP03AA SMA UC 9PIN PWR CABLE (2 REQ FOR PROT’N) 1HAU62501AAF X1SP20AA SMA UC/EX 3PIN PWR CABLE (2 REQ FOR PROT’N) 1HAU62025AAM X1SP52AA EOW 1U SHELF POWER CABLE 1HAU62522AAN X1SP52B EOW/PSTN RACK UNIT 19 /ETSI RINGMASTER/SLAVE 1HAL60518ABR X1SP53BA KOP 8 x RJ45 PLUS EXTRACTOR TOOL 1MBB61427AAV X1SP53BB KOP 3 x D-TYPES for Comms/Aux/Ancillary Unit 1MBB61428AAX X1SU65ZA (1) Electrical SFP Connector KOP 2x45deg for 7000 Cable 1MBB61422AAK X1SU65ZB (1) Electrical SFP Connector KOP 2x45deg for 3002 Cable 1MBB61462AAV X1Notes:(1) To be ordered in conjunction with STM-1 Electrical SFP, SU65AA5.10 SPARES SP97**On certain occasions there is a need to order individual units for spares etc. In addition anumber of items are only available as part of a Saleable Entity (SE) or Manufacturable Entity(ME). These entities may themselves contain several other items, thus making it economicallyunattractive to order the full entity. To get around this problem a number of SEs have beencreated to enable individual items to be ordered.SP97AA Spare UC Subrack(with mounting KOP)1HAG60627AAV1MBB61388AAHSP97AB Spare UC Power/LCT LTU (9 pin) 1HAM61217AAKSP97AC Spare EX Subrack 03HAG00001AAXSP97AE Spare SMA16UC & EX Core A ADM Unit 03HAT00041AAQSP97AF Spare SMA1/4UC & EX Core/CCU Card 1HAT61105AAF1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 516Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT5.11 SMA UC AC POWER & BATTERY BACKUP5.11.1 AC POWER/BATTERY BACKUP UNIT SP03PThe AC Power & Battery Backup Unit allows the UC to be powered either from the mainssupply or from batteries in the event of a mains failure. The unit also allows for the charging ofthese batteries when the mains supply is restored. The unit indicates it’s status to the UC via theuser alarm interface.The AC Power & Battery Backup Unit is housed in a metal enclosure similar in size to that ofthe UC. This allows the unit to be mounted next to the UC in a st<strong>and</strong>ard ETSI rack, eitherhorizontally or vertically. The unit can be fitted with one or two sets of batteries, dependant onthe load <strong>and</strong> the required backup time.Figure 5.3 - SMA UC AC Power & Battery Backup UnitThe mains input requires an input voltage range of 85V to 265V AC. The output isapproximately 58V DC at a maximum current of 3.1A (180W), when running on mains.The capacity of one fully charged set of batteries is 7Ah at 48v, <strong>and</strong> for two sets of batteries14Ah at 48v. The battery back-up time is dependent on the load, but as an example thefollowing table shows the approximate times for different configurations (based on two sets ofbatteries being fitted):1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 517Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTCore/CCU, 2M trib x 2 & AUX 55W 12 HoursCore/CCU, Protection, 2M trib x 2 Generic trib* x 2 & AUX 100W 7 HoursCore/CCU, Protection, 2M trib x 2, Layer 2, AUX & fan 150W 4.5 Hours16 Core/CCU, 16 Protection, 2M trib x 2, L2 x 2, AUX & fan** 165W 4 HoursThe SE includes the AC Power & Battery Backup Unit, a 3 pin to 3 pin DC PowerInterconnection cable <strong>and</strong> an Alarm Cable. No batteries are included - please refer to Section5.11.2 for details.SMA UC AC Power & Battery Backup Unit 03HAN00007AAH X1DC Power Interconnecting Cable 03HAU00009AAJ X1Alarm Cable Assembly 03HAU00003AAV X1The DC Power interconnecting cable is used to connect the DC output from the AC Power &Battery Backup Unit to the DC input of the SMA UC 3pin Power/LCT LTU SP03DA. Thecable is approximately 30cm in length.The Alarm Cable connects between the Status Output connector on the AC Power & BatteryBackup Unit <strong>and</strong> the Alarm Input connector on the SMA UC. This cable is also approximately30cm in length.5.11.2 BACKUP BATTERY PACK SV30UThe AC Power & Battery Backup Unit SE does not contain any batteries so these must beordered separately.It is recommended that if possible these are procured locally due to their weight <strong>and</strong> thepotential airfreight transport difficulties associated with batteries.Each battery pack consists of four YUASA NP7-12FR sealed lead acid batteries. No otherbattery type should be used. These each have a capacity of 7Ah at 12v, so the set of fourbatteries have an overall capacity of 7Ah at 48v. Each battery has a weight of 2.4kg.For extended battery backup time a second set can be fitted to the AC Power & Battery BackupUnit as previously described, giving a capacity of 14Ah at 48v.The following SE contains a single set of four batteries.SDH Ext II Battery Pack 1MBB61085AAG X1End of section1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 518Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT6 TRAFFIC INTERFACESThere are two traffic interface types:-Optical Interfaces <strong>and</strong> Electrical Interfaces.Each of the above interfaces have optical connector options <strong>and</strong> electrical data rate options.The choices of Interface slots available are Line slots <strong>and</strong> Tributary Slots.There are a total of 4 line slots. These are associated with the Core/CCU <strong>and</strong> Protection cards(2 per) <strong>and</strong> the modules that plug into these slots are of the SFP size.There are essentially 4 tributary slots. 2 ‘generic’ slot are multi-purpose (apart from 2M traffic)whereas the other 2 are dedicated to provision of 2Mbit/s traffic. Tributary traffic interfaces areprovided either on the front of card or via traffic LTUs associated with the card.See Sections 6 for Non-Traffic Interfaces <strong>and</strong> Section 7 for Monitor points.6.1 LINE SLOTS6.1.1 OPTICAL SFP MODULESConnector:Location:Use:Protocol:LC connectorSFP type module plugged into 1 of two slots provided on the Core/CCU(1HAT61105AAF) <strong>and</strong> Core Protection (1HAT61114AAT) units.For Short <strong>and</strong> Long Haul Optical Line TransmissionOptical ITU-T G.957 S1.1,L-1.1,L1.2,S4.1,L4.1,L4.2,L4.1+,L4.2+ITU-T G.707, G.957-86.1.2 ELECTRICAL SFP MODULESConnector:Location:Use:DIN 1.0/2.3 co-axialSFP type module plugged into 1 of two slots provided on the Core/CCU(1HAT61105AAF) <strong>and</strong> Core Protection (1HAT61114AAT) units.For in-station electrical line transmissionElectrical spec: 75ohms unbalanced to ITU-T G.703Protocol: ITU-T G.7076.2 OPTICAL TRIBUTARY CARDSThe following cards are plugged into the generic trib slots S1_01 <strong>and</strong> S1_02.1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 601Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT6.2.1 STM-1 Optical Daughter Card ModulesConnector: 2 x BT COF 8A FC/PC or SC, monitor ports see Section 7Location:Use:Protocol:Fitted to Dual STM-1 Optical Card, 1HAT60878AATFor Short <strong>and</strong> Long Haul Optical Line TransmissionOptical/Electrical spec: ITU-T G.957 S1.1 & L-1.1/1.2ITU-T G.707, G.957-86.2.2 Conventional STM-1 OpticalConnector: 2 x BT COF 8A FC/PC or SC, monitor ports see Section 7.Location:Use:Protocol:Front mounted on STM-1 optical card 1HAT60791* variantsFor Short <strong>and</strong> Long Haul Optical Line TransmissionOptical/Electrical spec: ITU-T G.957 S1.1/1.2 & L-1.1/1.2ITU-T G.707, G.957-86.2.3 Quad STM-1 OpticalConnector:Location:Use:Protocol:8 x BT COF 8A FC/PC or SCFront mounted on Quad STM-1 optical TCM card SN66TQ,TR,TS,TTFor Long-Haul Optical Line TransmissionOptical/Electrical spec: ITU-T G.957 I1, S1.1, L-1.1/1.2ITU-T G.707, G.957-86.2.4 STM-4 OpticalConnector: 2x BT COF 8A FC/PC or SC, monitor ports see Section 7Location:Use:Protocol:Front mounted on STM-4 optical card 1HAT61008* variantsFor Short <strong>and</strong> Long Haul Optical Line TransmissionOptical/Electrical spec: ITU-T G.957 S1.1,L1.1, L1.1+,L1.2,L1.2+ITU-T G.707, G.957-81ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 602Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT6.3 ELECTRICAL TRIBUTARY CARDS (FRONT PANEL ACCESS)6.3.1 Conventional STM-1 ElectricalConnector: 3 x Siemens 1.0/2.3 co-axial including monitor port (See Section 7).Location:Use:Front mounted on STM-1 Electrical card 1HAT60803ABTFor in-station electrical line transmissionElectrical spec: 75ohms Unbalanced to ITU-T G.703Protocol: ITU-T .G7076.3.2 Dual STM-1 ElectricalConnector: 6 x Simmons 1.0/2.3 co-axial including monitor port (See Section 7).Location:Use:Front mounted on Dual STM-1 Electrical card 1HAT61004ABPFor in-station electrical line transmissionElectrical spec: 75ohms Unbalanced to ITU-T G.703Protocol: ITU-T G.7076.3.3 Quad STM-1 ElectricalConnector:Location:Use:8 x Siemens 1.0/2.3 co-axial.Front mounted on Quad STM-1 Electrical card 1HAT61059AAJFor in-station electrical line transmissionElectrical spec: 75ohms Unbalanced to ITU-T G.703Protocol: ITU-T G.7076.3.4 140Mbit/sConnector: 3 x Siemens 1.0/2.3 co-axial including monitor port (See Section 7).Location:Use:Front mounted on 140 Mbit/s Tributary cards – 1HAT60624BFE/CAPIn-station electrical line transmissionElectrical spec: 75ohms Unbalanced to ITU-T G.703Protocol:CMI1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 603Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT6.4 ELECTRICAL TRIBUTARY CARDS (LTU ACCESS)6.4.1 2Mbit/s BALANCED LTUAssociated with:Connector:64x2M Core Tributary Card 1HAT61107AAK/ABC2 x 78 Way D Type ConnectorLocation: Front mounted on 2 Mbit/s Balanced LTU –Front Panel(1HBA60832AAA)Use:In-station electrical tributary interfacesElectrical spec: 120ohms balanced to ITU-T G.703, ETS 300 166Protocol:HDB36.4.2 2Mbit/s UNBALANCED LTUAssociated with:Connector:Location:Use:64x2M Core Tributary Card 1HAT61107AAK/ABC64 x Siemens 1.0/2.3 co-axialFront mounted on 2 Mbit/s Unbalanced LTU –Front Panel1HBA60828AAXIn-station electrical tributary interfacesElectrical spec: 75ohms Unbalanced to ITU-T G.703Protocol:HDB36.4.3 34/45Mbit/s LTUAssociated with: 34Mbit/s Tributary card 1HAT60622BAN, Transmux card1HAT60979AAC or 45Mbit/s Tributary card 1HAT60623BAQ,Connector: 9 x Siemens 1.0/2.3 co-axial including monitor port (See Section 13).Location:Use:Front mounted on 34/45 Mbit/s LTU 1HAM61215AAHIn-station electrical tributary interfacesElectrical spec: 75ohms Unbalanced to ITU-T G.703Protocol:HDB3/B3ZS1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 604Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT6.4.4 140/155 Mbit/s UNBALANCED LTUAssociated with:140Mbit/s Tributary card (1HAT60624BFE/CAP) or Dual STM-1 TCMElectrical Tributary (1HAT61004ABP)Connector: 6 x Siemens 1.0/2.3 co-axial inc. monitor ports (2 off) (See Section 7).Location:Use:Front mounted on 140/STM-1 LTU 1HAM61228AACIn-station electrical tributary interfacesElectrical spec: 75ohms Unbalanced to ITU-T G.703Protocol:CMIEnd of section1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 605Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT7 NON-TRAFFIC EXTERNAL INTERFACESSee Sections 5 for Traffic interfaces <strong>and</strong> Section 7 for Monitor points.Non-traffic external interfaces are provided by front mounted connectors on the following :-1HAM61217AAK Power/LCT LTU (UC 9 pin)1HAM61217ABC Power/LCT LTU (UC 3 pin)03HAM00008AAX Power/LCT LTU (EX 3 pin)1HAT61106BAE (1) Comms/Aux/Ancillary Card03HAN00007AAH AC Power & Battery Backup UnitNote that a Power/LCT LTU is always fitted. The Comms/Aux/Ancillary card is optional.(1)1HAT61106AAH superseded by Enhanced Comms/Aux/Ancillary Card. See section 10.1 for details7.1 POWER/LCT LTU INTERFACES7.1.1 POWER (UC 9 pin)Connector:Indicators:Use:2 x 9 way (male) ‘D’ type2 x Green LEDs, one for each inputRack DC supply inputsElectrical spec: prETS 300 132 <strong>and</strong> BTR 2511Ext connection:Via cable assembly 1HAU62501AAF7.1.2 POWER (UC 3 pin)Connector:Indicators:Use:2 x 3 way (‘Italtel’ 3W3A) ‘Power D’ type2 x Green LEDs, one for each inputRack DC supply inputsElectrical spec: prETS 300 132 <strong>and</strong> BTR 2511Ext connection:Via cable assembly 1HAU62025AAM7.1.3 POWER (EX 3 pin)Connector:Indicators:Use:1 x 3 way (‘Italtel’ 3W3A) ‘Power D’ type1 x Green LEDsRack DC supply inputs1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 701Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTElectrical spec: prETS 300 132 <strong>and</strong> BTR 2511Ext connection:Via cable assembly 1HAU62025AAM7.1.4 LOCAL CRAFT TERMINAL INTERFACEConnector:Use:Electrical spec:Protocol:Ext connection:8 pin RJ45 SocketLocal Terminal interfaceV.24 (RS232)Full-Duplex Asynchronous serial comms (Marconi Comms Proprietary)Via cable 1HAU61913AAF provided in SV30J7.2 COMMS/AUX/ANCILLARY CARD INTERFACES7.2.1 ELEMENT MANAGER CLNS1 (Q/B3) InterfaceConnector:Use:Electrical spec:Protocol:1 x 8 pin RJ45Ethernet LAN MV36 interfaceIEEE 802.3 st<strong>and</strong>ardOSI 7-layers conforming to ITU-TSS G.773 (Q.811 /Q.812)’B3’ stack7.2.2 AUXILIARY INTERFACESConnector:Use:2 x 8 pin RJ45 SocketExternal Interface to the 2 x 64Kbit Auxiliary InterfacesElectrical spec: V.117.2.3 2Mbit/s TEST BUSConnector:Use:Electrical spec:1 x 8 pin RJ45 SocketTo monitor 1 of the 64 core 2M Trib channelsG.703.7.2.4 EXTERNAL TIMING INPUTSConnector:2 x 8 pin RJ45 Connector1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 702Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTUse:Electrical spec:Protocol:To Synchronise the Ultra Compact to an External timing source.120 ohms balanced or 75 ohms unbalanced to ITU-TSS G.703, prETS300 166 (Both provided on connector).G.703 section 10 2048kHz NRZ or G.703 Section 6 HDB37.2.5 EXTERNAL TIMING OUTPUTSConnector:Use:Electrical spec:Protocol:2 x 8 pin RJ45 ConnectorTo Synchronise external equipment to the Ultra Compact.120 ohms balanced or 75 ohms unbalanced to ITU-TSS G.703, prETS300 166 (Both provided on connector).G.703 section 10 2048kHz NRZ or G.703 Section 6 HDB37.2.6 BW7R Alarm SchemeConnector:Use:Specification:1 x 15-way “D” type FemaleRack interface to Light Signalling Equipment <strong>and</strong> remote SupervisionConsole.As Marconi Communications System Interface Spec 1ADA60638AAR-BSA.7.2.7 User Output InterfaceConnector:Use:Specification:1 x 9-way “D” type Male4 off general purpose alarm outputs, which can be enabled or disabledvia LCT).As Marconi Communications System Interface Spec 1ADA60638AAR-BSA.7.2.8 User Input InterfaceConnector:Use:Specification:1 x 15-way “D” type Male6 off general purpose alarm inputs. (Raises alarm on LCT).As Marconi Communications System Interface Spec 1ADA60638AAR-BSA.1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 703Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT7.3 AC POWER & BATTERY BACKUP UNIT7.3.1 Mains InputConnector: IEC 320Use:Electrical spec:Mains Power Inlet.85v to 265v AC, 47-65Hz.. Max power consumption 240W7.3.2 DC OutputConnector:Use:Electrical spec:‘Reversed’ 3W3A Italtel Power D Type48v DC (nom) output to power UC.48v DC (nom).7.3.3 Alarm/Status OutputConnector:Use:Protocol:15 way Male D TypeAlarm/Status output from AC Power/Battery Backup UnitFor connection to SMA UC Alarm InputEnd of section1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 704Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT8 MONITOR POINTS & TEST BUSSee Sections 5 for Traffic interfaces.8.1 34/45MBIT/SConnector:Location:Use:Electrical spec:1 x Siemens 1.0/2.3 co-axial. per Port (3 per LTU)Front mounted on the 34/45M LTU 1HAM61215AAFOutput signal monitor point.Attenuated representation of the signal at the Tributary traffic portProtocol: HDB3 34Mbit/sB3ZS 45Mbit/s8.2 140/155MBIT/SConnector:Location:Use:Electrical spec:Protocol:1 x Siemens 1.0/2.3 co-axial per port (2 per LTU)Front mounted on the 140/155M LTU 1HAM61228AACOutput signal monitor point.Attenuated representation of the signal at the Tributary traffic portCMI8.3 CONVENTIONAL STM-1 OPTICALConnector:Location:Use:Electrical spec:2 x Siemens 1.0/2.3 co-axial.Front mounted on the STM-1 Optical & DWDM cards (see Section 5 forcodes)Output signal <strong>and</strong> clock monitor points.Electrical representation of the signal at the traffic portProtocol: ECL Logic Levels, ITU-T G.707, G.957-8-9(draft) .8.4 DUAL STM-1 OPTICAL AND QUAD STM-1 OPTICAL/ELECTRICALNo monitor points are available on the front plate of these cards (see Section 5 for codes)No monitor points are available on the front plate of the Quad Electrical card (see section 5 forcode).1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 801Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT8.5 CONVENTIONAL STM-1 ELECTRICALConnector:Location:Use:Electrical spec:1 x Siemens 1.0/2.3 co-axial.Front mounted on the STM-1 Electrical card (see Section 5 for code).Output signal monitor point.Attenuated representation of the signal at the traffic portProtocol: CMI, ITU-T G.7078.6 DUAL STM-1 ELECTRICALConnector:2 x Siemens 1.0/2.3 co-axial.Location: Front mounted on the Dual STM-1 Electrical card (see Section 5)Use:Electrical spec:Output signal monitor points.Attenuated representation of the signal at the traffic portProtocol: CMI, ITU-T G.7078.7 2MBIT/S TESTBUSConnector:Use:Electrical spec:1 x 8 pin RJ45 SocketTo monitor 1 of the 64 core 2M Trib channelsG.703.Location: Front mounted on Comms/Aux/Ancillary Card 1HAT61106BAE (1)Protocol:HDB3(1)1HAT61106AAH superseded by Enhanced Comms/Aux/Ancillary Card. See section 10.1 for detailsEnd of section1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 802Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT9 COMMUNICATIONSThe Comms/Aux/Ancillary Card 1HAT61106BAE (1) provides customer access to thecommunications functions on the SMA-1/4UC. Network management message h<strong>and</strong>ling <strong>and</strong>message routing to network elements is performed by the Core/CCU unit.The communications protocol between the Network Elements <strong>and</strong> the GatewayMultiplexer/Element Manager is based on the ISO Open Systems Interconnect 7-layer model.The Comms/Aux/Ancillary Card (SP53B) provides an Ethernet interface (10/100baseT) via aRJ45 type connector for connection to MV36.Messages for/from other network elements are routed over the overhead access busses <strong>and</strong> areembedded into the line signal using the STM1 SOH DCC channels (CCITT G784 Qeccinterfaces). Overhead busses interface to the Core/CCU Card, each being able to carry a DCCchannel (DCCr[192kbit/s] <strong>and</strong> DCCm[576kbit/s]). The choice of DCC data rate should bedetermined during Element Manager system design.From R3.4 rev it is also possible to transport a DCC channel via a 2Mbit/s port using theEnhanced Comms/Aux/Ancillary card, please refer to section 10.1 for full details.(1)1HAT61106AAH superseded by Enhanced Comms/Aux/Ancillary Card. See section 10.1 for details9.1 IS-IS TABLE SPACEProductSMA-1/4UCAvailable IS-IS Table SpaceEnd of section1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 901Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT10 AUXILLARY AND ANCILLARY FUNCTIONALITYOne slot is provided for the Comms/Aux/Ancillary card (SP53B)This allows omnibus h<strong>and</strong>ling of client telemetry data, via RTU’s (Remote Terminal Unitsused for <strong>control</strong>ling equipment such as C-MUX primary multiplexers) or MCU’s(ManagementCommunications Units), both around an SDH ring <strong>and</strong> on STM-n tributaries. This is achievedby inserting <strong>and</strong> extracting Auxiliary data between discrete 64kbit/s I/O ports (from the client’sequipment) <strong>and</strong> Section Overhead bytes (SOH) of the SDH line interfaces.An enhanced version of the Comms/Aux/Ancillary card is available from Q1 2006. Thisenhanced card is fully backwards compatible with the original card, but also offers E1 OLOcommunications <strong>and</strong> configurable Bw7R alarm outputs. The E1 OLO comms feature allows aDCC communication channel to be mapped into a G.704 2Mbit/s frame for transport via2Mbit/s tributary port.10.1 COMMS/AUXILIARY/ANCILLARY CARD (SP53B)The Comms/Aux/Ancillary Card 1HAT61106BAE provides customer access to twoasynchronous bi-directional 64kbit/s data channels. One card can be fitted per Subrack in thededicated Comms/Aux/Ancillary slot.These two 64kbit/s channels are routed to two line interfaces <strong>and</strong> there is no access to overheadbytes of tributary slots. Choice of line interface is either under operator comm<strong>and</strong> (LCT/NM)or Core/CCU <strong>control</strong> (when MSP is activated).The card is not connected to the SMA Control Bus, therefore it cannot be configured ormonitored via the EMOS/LCT. The Card has an Inventory PROM <strong>and</strong> a Card Presence signal,which will be de-activated, if the card is removed.To maintain auxiliary data continuity in, say, an SDH ring, if the Line East <strong>and</strong> Line Westauxiliary data is not to be accessed locally at a particular element, it has to be bypassed. Thedata can be patched through by externally wiring the appropriate connectors together.Alternatively it is possible to bypass Row 9 Column 8 data only via LCT/NM configuration. Ifthis bypass option is chosen then the Comms/Aux/Ancillary card is not required.The E1 OLO comms feature offered by the enhanced Comms/Aux/Ancillary Card allows eitherDCCr (compatible with Huawei partner equipment) or DCCm communications to be carriedover the 2Mbit/s channel. This is selectable by hardware link. The E1 OLO channel isconnected via the backplane to port 32 of each 2M Tributary card, <strong>and</strong> the LCT/NM is used toconfigure the single 2M trib selected to carry the E1 OLO comms (from R3.4 rev 2).The enhanced Comms/Aux/Ancillary Card also allows configuration of some of the Bw7Routput pins, as requested by a number of customers. Again this is achieved by configuration ofhardware links on the card.Note: Comms/Auxiliary/Ancillary Card 1HAT61106BAE supersedes the original card1HAT61106AAH. The original card remains fully supported <strong>and</strong> offers all of the above listedfeatures except for E1 OLO Comms, which requires the enhanced 1HAT61106BAE card.1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1001Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT10.2 EXTERNAL EOW UNIT (SP52A)EOW functionality is provided by an external st<strong>and</strong>-alone unit (SP52A) which plugs into theComms/Aux/Ancillary card.A cable assembly (SP52AA) is available for connecting to the top of rack power supply.10.2.1 General FeaturesThe EOW unit provides an audio channel through the SMA by utilises the E1/E2 bytes withinthe STM-n SOH. The h<strong>and</strong>set interface for the EOW is a st<strong>and</strong>ard 2 wires analogue interfacewith DC current feed, hook status detection <strong>and</strong> DTMF signaling. A 4-wire analogue/digitalinterface is available to extend the EOW by means of another 4-wire analogue/digital interfacewith similar characteristics. This interface is available in order to EOW-connect twoequipments, which do not communicate by traffic linksThe External EOW unit provides:-• Analogue EOW access via a 2-Wire interface• EOW reset <strong>and</strong> Control via buttons• Analogue EOW access via a 4-Wire interface• EOW telephone number <strong>control</strong>• EOW ring Master/Slave Control• EOW Call arrival buzzer <strong>and</strong> relay output signals for extending locally• Status readout via LEDs <strong>and</strong> external Alarm outputs• Dual 64kbit/s clock <strong>and</strong> data interfaces (Port 1 <strong>and</strong> Port 2)10.2.2 External EOW Unit InstallationAn outline drawing of the external EOW unit is shown below (Figure 10.1). The Unit occupiesa full rack width <strong>and</strong> is suitable for rack mounting in an ETSI (600mm) <strong>and</strong> 19” racks.The unit is supplied with two mounting brackets <strong>and</strong> fixings.The EOW Unit occupies 1U vertical x rack width x 75mm (Max) depth into rack.H<strong>and</strong>set Status LEDs Intrude Reset LCT Relay 4-Wire 64K Power EarthButtons Digital StudFigure 10.1 - External EOW Unit LayoutNote, all connections are made to the front of the unit.1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1002Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT10.2.3 Battery SupplyA single 3-pin DIN connector is used for the Battery supply for the primary power source(-48V DC nominal, -29V to –75V DC).A cable assembly (SP52AA) is available for connecting to the top of rack power supply.10.2.4 Digital InterfacesTwo 64kbit/s interfaces are provided by two 8-pin RJ45 connectors. These are cabled up to thetwo AUX ports (AUX1 <strong>and</strong> AUX2) on the SMA equipment.10.2.5 H<strong>and</strong>set (2-Wire) ConnectorsThe h<strong>and</strong>set is connected into the either of the Dual 2-Wire interfaces. A 6-pin RJ11 connector<strong>and</strong> an ADC Bantam PC834J Stereo Phonejack connector are provided.10.2.6 Analogue (4-Wire) ConnectorA Single 4-Wire interface is provided on an 8-pin RJ45 connector. The port is configured usinga “dumb” terminal (see 10.2.8).10.2.7 External Relay ContactRelay contacts, NC, NO <strong>and</strong> the relay 'Pole' are provided <strong>and</strong> can be connected via the RJ45connector.10.2.8 Local TerminalA single RJ45 connector is provided for the connection of a local 'dumb' terminal.Using a dumb terminal it is possible to configure the EOW unit as a Ring Master or Slave, toset up the Unit Telephone number <strong>and</strong> to enable the 4-Wire port.End of section1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1003Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT11 LOCAL TERMINAL AND ELEMENT SOFTWAREThere are two main software components to the system.One is the Network Element software containing individual software modules for each of thecard types <strong>and</strong> the other is the Local Terminal management software.During operation the Element Software is stored on a Compact Flash type System Memorydevice pushed into a connector on the Core/CCU card.The purpose of the Local Terminal is to provide all the functions necessary to locallyconfigure, <strong>control</strong> <strong>and</strong> monitor each SMA subrack. The Local Terminal comprises applicationsoftware running on an IBM compatible PC interfacing to the equipment subrack via a cable.The user performs operations on the apparatus via the keyboard or mouse.Individual Compact Flash Saleable Entities are available for each release of product software.The LCT software is provided on a CD-ROM. Also contained on the CD-ROM is NetworkElement software to allow on-site upgrade of existing earlier releases of Compact Flash.Each separate release of software (e.g. R3.1, R3.2 R3.3.1 etc.) will have its own uniqueelement software build (i.e. that stored on the Compact Flash System memory device) <strong>and</strong> alsoLCT. It is essential for reasons of compatibility that corresponding LCT <strong>and</strong> Elementsoftware builds must be used. That is R3.2 Element Software must be used with R3.2LCT etc.11.1 LCT HARDWAREComputerNH40JNH40KNH40FNH40GNext Generation LCT with Windows 2000 + Card ReaderNext Generation LCT with Windows XP + Card ReaderLocal Craft terminal Hardware with Windows 2000 (WITHDRAWN Do Not use)Local Craft terminal Hardware with Windows XP (WITHDRAWN Do Not use)Notes:-1) NH40F <strong>and</strong> NH40G have been superseded by NH40J <strong>and</strong> NH40K respectively. Theyshould not be ordered <strong>and</strong> are only shown here for reference.2) The network element System Memory is stored on a <strong>compact</strong> Flash device in the UC & EXproduct range. Maintenance upgrades of element software continue to be supported bysoftware download. However, major updates such as a change of revision of elementsoftware can now be accomplished much faster by the direct reprogramming of the<strong>compact</strong> flash. To this end the new LCT hardware entities NH40J/NH40K come readyequipped with a ‘card reader’ to enable this reprogramming to be carried out.3) In cases where customer already have the older NH40F/NH40G a separate st<strong>and</strong>-alone cardreader is provisioned by NH40H below.Compact Flash ProgrammerNH40HExternal USB Card Reader for use with LCT NH40F/G1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1101Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTThis is a st<strong>and</strong>-alone Compact Flash programmer that plugs into the USB port of the PC.CablesSV30JSMA1/4CP, SMA1/4c <strong>and</strong> SMA1/4UC Local Craft Terminal CableThe cable provided for the above is Belden 9502 (1WAD20028AAL) which contains 2 offtwisted pairs of 24AWG PVC insulated wires with overall screen <strong>and</strong> drain wire or equivalent.It is used to connect between the PC <strong>and</strong> the RJ45 type LCT connector on the front of theSMA1/4UC.11.2 LCT & BACKUP SOFTWAREThe Local Terminal Software is executed from the hard drive on the PC to provide the LocalTerminal functions for the SMA products.The LCT software is supplied on a CD-ROM, which must first be installed onto the hard driveof the PC. The CDROM also includes backup software, of the release in question, for the actualelement (i.e. the software stored in the Compact Flash device).SP81C SMA UC REL 3.1 Backup & LCT Software CD-ROMSP81CA SMA UC REL 3.2 Backup & LCT Software CD-ROMSP81CB SMA UC & EX REL 3.3.1 Backup & LCT Software CD-ROMSP81CB (1) SMA UC & EX REL 3.3.2 Backup & LCT Software CD-ROMSP81CF SMA UC & EX REL 3.4 Backup & LCT Software CD-ROM1) R3.3.2 CD-ROM will also contain R3.3.1 software therefore SE stays the same.2) Rel 3.3.2 & Rel 3.4 also support SMA16UC <strong>and</strong> SMA16EX products.11.3 LCT OPERATING SYSTEMThe Operating System required for use with the Local Terminal software is Windows 2000 orWindows XP.11.4 NETWORK ELEMENT SOFTWAREThis is stored on a Compact Flash memory device, which should be housed in the connector onthe Core/CCU card. Different releases of software have different Compact Flash saleableentities. The Compact flash memory device is no longer supplied as part of any Core SE <strong>and</strong>must be ordered separately.SP03SASP03SCSP03SDSP03SESP03SFSMA1/4UC Rel 3.1 Compact FlashSMA1/4UC Rel 3.2 Compact FlashSMA UC & EX Rel 3.3.1 Compact FlashSMA UC & EX Rel 3.3.2 Compact FlashSMA UC & EX Rel 3.4 Compact Flash1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1102Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT11.5 CELLSPAN CARDSCurrently not supported on SMA UC & EX product range.11.6 PACKETSPAN CARDSThe Packetspan software is provided on card <strong>and</strong> unit where applicable, <strong>and</strong> is programmed inthe factory or by software download. Firmware is held on the card <strong>and</strong> not on the CompactFlash System Memory device.Refer to Packetspan Provisioning Control Document 03ADR00001AAF-CTA for full details.11.7 LAYER 2 CARDSThe Layer 2 Card software is provided on card <strong>and</strong> unit where applicable, <strong>and</strong> is programmedin the factory or by software download. Firmware is held on the card <strong>and</strong> not on the CompactFlash System Memory device.Refer to Layer 2 Provisioning Control Document 05ABA00001AAL-CTA for full details.End of section1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1103Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT12 CARD FACIAOn those units unique to this product, facias are always fitted during manufacture. There are nooptions in terms of facia type or fit/not fit.Existing SMA units may or may not have options. The relevant SE structure should beconsulted.End of section1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1201Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT13 EMC COVERSA SMA subrack must have all card slot positions <strong>and</strong> all LTU positions fitted to maintain theEMC performance of the equipment.13.1 UNEQUIPPED SLOT COVERSFollowing the equipping of the subrack with required cards <strong>and</strong> LTUs, extra EMC covers maybe needed:SP73B EMC Cover Core 1MBA62249AABSP73C EMC Cover Comms/Aux/Ancillary 1MBA62250AAWSP73EB EMC Cover 2M Trib 1MBA62253AADSP73DB EMC Cover 2M LTU 1MBA62252AABSP73EA EMC Cover Generic Trib 1MBA61103ABSSP73DA EMC Cover Generic LTU 1MBA62251AAYSP73G EMC Cover EX 2M LTU Single 03MBA00068AAKSP73H EMC Cover EX 2M LTU Triple 03MBA00069AAMWhen any cards <strong>and</strong>/or LTUs are ordered for inclusion in the subrack <strong>and</strong> there is a core EMCcover already fitted the appropriate cover should be discarded or re-cycled.Note:- There is an EMC cover associated with the Fan slot. However, this cover(1MBA62266AAA) is provided within the SMA1/4/16UC Cores SP03AB & SP13AB.End of section1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1301Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT14 MECHANICAL DETAILSThe subrack is a card cage mechanical design meeting the ETSI st<strong>and</strong>ard ETS 300 119 Part-4<strong>and</strong> screened for EMC according to ETSI requirements ETS 300 119 Part 2/4.14.1 SUBRACK MOUNTINGThe SMA1/4/16 UC subrack can be mounted in a number of racks:-1. ETSI –Right h<strong>and</strong> side or Left h<strong>and</strong> side2. 19” –Right h<strong>and</strong> side or Left h<strong>and</strong> side3. Horizontally mounted in a ETSI rack4. Horizontally mounted in a 19” rack5. DIN 19 “ - Right h<strong>and</strong> side or Left h<strong>and</strong> side6. Horizontally mounted in a DIN 19” rackIf mounted vertically, 2 subracks may be fixed side by side.The 19” rack is for a st<strong>and</strong>ard telecomms type 19” rack which has a 600mmcabinet/535mm throat, whereas the DIN 19” meet the requirement for the Germanmarket.Options 1-4 are accommodated by the mounting brackets kit of parts 1MBB61388AAHsupplied as part of the core UC system. See sections 5.1.1 & 5.1.3.Options 5-6 are accommodated by the mounting brackets kit of parts 1MBB61388BAEsupplied as a separate saleable entity (SP03C) See section 5.9If mounted horizontally then a fan unit must be fitted. Refer to Section 5.2.1.3 for full details.Note:- The brackets meet the requirements for office vibration only. They have not beentested against extended requirements for earthquake zones.14.2 UNIT DIMENSIONSThe attached table shows the approximate dimensions of the SMA1/4UC specific units.SMA1/4UC Unit Type Height (mm) Depth (mm) Width (mm)1HAG60627AAV SMA1/4UC SUB RACK 445 280 2181HAT61105AAF Core/CCU Card 254 229 331HAT61106AAH/BAE Comms/AUX/Ancillary Card 254 229 39.51HAT61107AAK/ABC 64x2M Core Trib Card 254 229 221HBA60827AAV 32x2M Unbalanced LTU –Interface module1HBA60828AAX 32x2M Unbalanced LTU –Front panel147(Combined)117(Combined)71(Combined)1HBA60831AAX 32x2M Balanced LTU –Interface module1HBA60832AAA 32x2M Balanced LTU –Front panel147(Combined)117(Combined)71(Combined)1HAM61215AAF 3x34M LTU 147 117 211HAM61217AAK Power/LCT LTU (9 pin) 147 117 211HAM61218ABC Power/LCT LTU (3 pin) 147 117 211HAM61218AAM Generic Trib Power LTU 147 117 211HAT61114AAT Protection Core Card 254 229 331HAM61219AAP Fan Assembly (SMA1/4UC) 22 222 21403HAN00007AAH AC Power & Battery Backup Unit 445 177 2181400729-***** & 1400744-**** SFP Optical Line Module 11 13 631HAL60517AAW STM-1 Electrical Module DIN 1.0/2.3 11 13 631ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1401Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT1HAM61228AAC 2 x STM-1/140M LTU 147 117 2103HAG00001AAX EX Subrack 445 278 44903HAM00008AAX EX Power/LCT LTU 147 117 2203HAT00056AAQ EX 63x2M Trib Card 254 228 2503HAM00003AAL EX 63x2M Unbal LTU 147 124 14103HAM00002AAJ EX 21x2M Bal LTU 151 121 1903HAT00043AAU Multirate Trib Card 254 228 2503HAT00041AAQ STM-4/16 Core A/CCU ADM Unit 254 232 3803HAT00041ABH STM-4/16 Core B ADM Unit 254 232 3803HAM00009AAA EX Vertically Extended 63x2M Unbal LTU 315 124 8214.3 WEIGHTSUnit/Card Weights:CardsCard Weight(kg)UC Specific1HAG60627AAV SMA1/4UC SUB RACK 2.91HAT61107AAK/ABC 64x2M Core Trib Card 0.391HBA60827AAV 32x2M Unbalanced LTU –Interface module 0.071HBA60828AAX 32x2M Unbalanced LTU –Front panel 0.181HBA60831AAX 32x2M Balanced LTU –Interface module 0.111HBA60832AAA 32x2M Balanced LTU –Front panel 0.111HAM61217AAK Power/LCT LTU (9 pin) 0.121HAM61217ABC Power/LCT LTU (3 pin) 0.1203HAN00007AAH AC Power & Battery Backup Unit (no batteries fitted) 5.2EX Specific03HAG00001AAX EX Subrack 7.4603HAM00008AAX EX Power/LCT LTU 0.2503HAT00056AAQ EX 63x2M Trib Card 0.4303HAM00003AAL EX 63x2M Unbal LTU 0.6303HAM00002AAJ EX 21x2M Bal LTU 0.1703HAM00009AAA EX Vertically Extended 63x2M Unbal LTUTBCUC & EX Generic1HAT61105AAF Core/CCU Card 0.51HAT61106AAH/BAE Comms/AUX/Ancillary Card 0.71HAM61215AAF 3x34M LTU 0.181HAM61218AAM Generic Trib Power LTU 0.151HAT61114AAT Protection Core Card 0.51HAM61219AAP Fan Assembly (SMA1/4UC) 0.51400729-***** & 1400744-**** SFP Optical Line Module 0.0121HAL60517AAW STM-1 Electrical Module DIN 1.0/2.3TBC1HAM61228AAC 2 x STM-1/140M LTUTBC03HAT00043AAU Multirate Trib Card 0.4003HAT00041AAQ STM-4/16 Core A/CCU ADM Unit 0.8003HAT00041ABH STM-4/16 Core B ADM Unit 0.80SMA Generic1HAT60622BAN 34Mbit/s Tributary Card 0.41HAT60623BAQ 45Mbit/s Tributary Card 0.41HAT60624BFE/CAP 140Mbit/s Tributary Card 0.41HAT60979AAC 34Mbit/s Transmux 0.421HAT60917AAG VCTS VCAM Card (EXTENDER I&II) 0.441HAT60791* STM-1 Optical Card TCM 0.461HAT60878AAT Dual STM-1 Optical card, without optics fitted 0.38SN66TQ,TR,TS,TT Quad STM-1 Optical Card for SMA-1/4c 0.551HAT60803ABT STM-1 Electrical Card 0.41HAT61004ABP Dual STM-1 Electrical Card 0.381ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1402Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT1HAT61059AAJ Quad STM-1 Electrical Card 0.451HAT61008*** STM-4 Optical CardTBC14.4 RECOMMENDED RACKS FOR HOUSING SMA SUBRACKS/UNITSRecommended ETSI racks <strong>and</strong> Racking installation kits of parts can be found in ref0.5.16Provisioning Control Document for ETSI Rack <strong>and</strong> Associated Parts 1ADR60674AAX-CTA.NOTE: Other racks not listed may be used to house SMA Subracks but consideration shouldbe given to the provision of suitable mounting brackets <strong>and</strong> the availability of adequate accessfor fibre or co-axial cables from the rack cable route to the subrack connection points. e.g. onsome rack types the cable route may be blocked by the relative positions of the rack <strong>and</strong>subrack metalwork, especially important when subracks are mounted back to back..CAUTION: The rack chosen should allow the SMA subrack to have the rack front coversfitted in normal operation, this is to provide ESD protection <strong>and</strong> assist air flow throughthe rack for natural convection cooling. See also Section 17 details.A fan tray should always be fitted in the SMA1/4 Ultra Compact when it is mountedhorizontally. Please refer to Section 5.2.1.3 for full fan tray equipping rules.14.5 OPTICAL FIBRE AND CABLE DRESSINGCAUTION: For racks requiring full functionality, careful consideration must be given tothe management of cabling by the use of suitable cable ducting.14.6 SUBRACK INSTALLATIONRefer to the ‘Installation Guide for SDH Transmission Equipment’ 1QDE10274AAU-YYA for furtherinformation.End of section1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1403Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT15 RECOMMENDED CABLES, CONNECTORS, CABLE ASSEMBLIES AND KITS OF PARTSA number of external connection points are provided on the equipment. These give access to traffic interfaces, synchronisation ports, managementports etc. as detailed in sections 5, 6 <strong>and</strong> 7. It is important to ensure that the correct cables <strong>and</strong> connectors are used to connect to these interfaces.15.1 RECOMMENDED CABLESGiven below is a list of recommended cables that may be used. The list is not exclusive but FAILURE to use cables of this type with comparableelectrical properties may result in the installation not being fully compliant with EMC regulations.Connectors can be purchased in pre-packaged kits of parts or in the case of balanced 2M a pre-formed cable assembly is also available. (See laterthis section)15.1.1 Traffic InterfacesCard TypeCableHFE2290 BT3002 (Note1) BT2003(Note 2) ST212 (Note 1) ST214 (Note 2) RA70001WAE20028AAX 1WAE20002AAE 1WAE00005AAW 1WAE20031AAX 1WAE20030AAV 1300903-00352M Unbalanced LTU Y Y N Y N T.B.A.34/45M LTU Y N Y N Y T.B.A.140/155M LTU Y N Y N Y T.B.A.140/155M Front plug up Y N Y N Y T.B.A.STM-1 Elec. SFP N N N N N YNotes:-1) BT3002/ST212 not recommended for 34/45/140/155 due to increased attenuation2) BT2003/ST214 not recommended for 2M due to its large diameter1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1501Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT15.1.2 Non-Traffic InterfacesInterface Type Quantity Cable Connector Type Cable Type Cable CodeComms/Aux/AncillaryUnbalanced Sync (note 1) 2 RJ45 75 Ohm Coax 1WAE20004AAJAux 2 RJ45 Screened pair cable 1WAD20062AAJ(4pair)Balanced Sync (note1) 2 RJ45 Screened pair cable 1WAD20062AAJ(4pair)2M Test Bus 1 RJ45Network Management 1 RJ45 Screened pair cable 1WAD20062AAJ(4pair)User Output 1 9 way D-type Male User defined User definedUser Input 1 15 way D-type Male User defined User definedAlarms 1 15 way D-type Female User defined User definedUC PWR/LCTLCT cable 1 RJ45 N/A Use1HAU62913AAFSubrack Power (9 pin LTU) 2 9 way D-type Female N/A Use1HAU62501AAFSubrack Power (3 pin LTU) 2 3-way Power D-type, 2Female ContactsN/AUse1HAU62025AAMComment [JB1]: This is notacceptable. Cables need to bescreened & have appropriateshielded back-shells to maintainEMC compliance!Comment [JB2]: As above.Comment [JB3]: As above.EX PWR/LCTLCT cable 1 RJ45 N/A Use1HAU62913AAFSubrack Power 2 3-way Power D-type, 2Female ContactsN/AUse1HAU62025AAMNotes:-1) Each of the 2 sync connectors provides access to both balanced <strong>and</strong> unbalanced sync. Wiring <strong>and</strong> choice of cable determines which interface is implemented.1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1502Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT15.1.3 Cable DetailsCABLE:CODE:TYPE:USE :NOTE:CABLE:CODE:TYPE:USE :NOTE:HFE 2290 Cable 1 or Siemens Cable V45466-D13-C15 or V23614-A102-A761WAE 20028 AAX75 Ohm Double Screened co-axialUnbalanced connections to all Tributary ports, however the attenuation characteristics must be checked before use.Max dist. 2M – 330m, 34M – 170m, 45M – 150m, 140M – 85m, STM-1 – 80mNote: Typical cable may support 5-10% extra length but is not guaranteedBT 3002 Cable1WAE 20002 AAE75 Ohm Double Screened co-ax to CW1383AUnbalanced connections to 2M Tributary portsSignals up to 2Mbit/s, short lengths may be acceptable above 2Mbit/s however the attenuation characteristics must bechecked before use <strong>and</strong> no EMC compliance above 2Mbits is offered by Marconi Communications (for BT)CABLE:BT 2003 CableCODE:1WAE 00005 AAWTYPE: 75 Ohm Double Screened co-ax (low loss)USE :Unbalanced connections to Line <strong>and</strong> Tributary portsNOTE:Signals above 2Mbit/s (for BT). Not recommended for 2M ports due to the relatively large cable diameter whichmakes cable routing within the rack difficult when a large number of ports are utilised.CABLE:CODE:TYPE:USE :NOTE:ST212 Cable1WAE 20031 AAX75 Ohm Double Screened co-axUnbalanced connections to Tributary <strong>and</strong> Sync portsSignals up to 2Mbit/s (for Italtel). Short lengths may be acceptable above 2Mbit/s however the attenuationcharacteristics must be checked before use <strong>and</strong> no EMC compliance above 2Mbits is offered by MarconiCommunications.1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1503Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTCABLE:CODE:TYPE:USE :NOTE:ST214 Cable1WAE 20030 AAV75 Ohm Double Screened co-ax (low loss)Unbalanced connections to Tributary/Line portsSignals above 2Mbit/s (for Italtel). Not recommended for 2M ports due to the relatively large cable diameter whichmakes cable routing within the rack difficult when a large number of ports are utilised.CABLE:Belden 9806 cableCODE:1WAD 20062 AAJTYPE: Screened Pair Cable (4 pair)USE :Connections to balanced Sync, Auxiliary, Alarm <strong>and</strong> Network Management portsNOTE:100-120 Ohm balanced signals up to 2Mbit/sCABLE: Coaxial 7/0.1mmCODE:1WAE20004AAJTYPE:75ohm coaxialUSE :Connections to unbalanced RJ45 Sync ports.NOTE:75 Ohm unbalanced sync signalsCABLE:Raydex RA7000 cableCODE: 1300903-0035TYPE:75ohm coaxialUSE :Connections to STM-1 SFP electrical modules.15.2 PRE MADE CABLE ASSEMBLIESThe following st<strong>and</strong>ard pre-made cable assemblies have been created to ease installation.POWER Cable Assembly – SMA1/4UC (9 pin) (SP03AA)CODE:1HAU62501AAFTYPE:Multicore (x9) 20AWG (0.56mm 2 1WAD20141AAH) terminated with 9 way D Type1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1504Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTUSE:NOTE:Power cable between PWR/LCT unit (9 Way D-Type) <strong>and</strong> SMA1/4UC top of rack power supply (breakout).2 off required for protected battery supplies.POWER Cable Assembly – SMA1/4UC/EX (3 pin) (SP20AA)CODE:1HAU62025AAMTYPE:Two-Core 8 AWG (4mm 2 - 1WAD20128AAS) terminated with 3 pin 3W3A Power D TypeUSE:Power cable between PWR/LCT unit (3Way Power D-Type) & SMA1/4UC/EX top of rack power supply (breakout).NOTE:2 off required for protected battery supplies.2M Balanced LTU cable assembly 3m (MP93CC03)CODE:1HAU62508AAV (3 m length)TYPE:Screened Pair Cable (32 pair) terminated with 78way sub-miniature D typeUSE:Connections to balanced 2M Tributary ports,NOTE:Assembly pack consists of two separate cables, each of which is terminated with a D-type at one end. This gives a total2M balanced port connectivity of 32 channels. (i.e. 32 inputs <strong>and</strong> 32 outputs).2M Balanced LTU cable assembly 20m (MP93CC20)CODE:1HAU62508ABN (20m length)TYPE:Screened Pair Cable (32 pair) terminated with 78way sub-miniature D typeUSE:Connections to balanced 2M Tributary ports,NOTE:Assembly pack consists of two separate cables, each of which is terminated with a D-type at one end. This gives a total2M balanced port connectivity of 32 channels. (i.e. 32 inputs <strong>and</strong> 32 outputs).CABLE:CODE:TYPE:USE:CABLE:CODE:TYPE:USE:LCT Cable Assembly (SV30J)1HAU61913AAFBelden 9502 or equivalent, 8 way.Local terminal interface for SMA1/4UC, SMA1/4CP <strong>and</strong> SMA1/4cEOW 1U Shelf Power Cable (SP52AA)1HAU62522AAN3 Core (1.5mm Sq.) CU PVC 3 x 30/0.25 SCN 16A (1WAD20122AAE)Power Cabling between EOW unit <strong>and</strong> SMA1/4UC top of rack power supply1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1505Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT15.3 CONNECTOR KITS OF PARTSA number of kits of parts containing multiple connectors are available <strong>and</strong> these are listed belowNotes:-1. Right angled connectors are not recommended for LTU connections as the PCB connectors on the actual LTUs tend to be too close together.2. All the traffic coax connectors listed below are of type 1.0/2.3 male. 2 are required per interface (i.e one input <strong>and</strong> one output).SaleableEntitySP53BASP53BBDescription ME Code MEQtyKOP 8 x RJ45 Plus Extractor tool(For use with e.g.Comms/Aux/Ancillary Unit.)KOP 3 x D-Types(For use with e.g.Comms/Aux/Ancillary Unit.)SE Contents1MBB61427AAV 1 8 x RJ 45Extractor tool (for extracting RJ45 connectors fromthe Comms/Aux/Ancillary unit)1MBB61428AAX 1 1 x 9 way D Type Male1 x 15 way D Type Male1 x 15 way D Type FemaleD-Type hoodsSU65ZA Electrical SFP Connector KOPs 1MBB61422AAK 1 2 x 45deg Male 1.0/2.3 for 7000 cableSU65ZB Electrical SFP Connector KOPs 1MBB61462AAV 1 2 x 45deg Male 1.0/2.3 for 3002 cableMP93AA Straight ST214 1 port 1MBB60851AAJ 1 2 x straight ST214MP93BB Straight HFE2290 1 port 1MBB60891AAU 1 2 x straight HFE2290MP93BC Straight BT2003 UK std 1 port 1MBB60912AAG 1 2 x straight BT2003 St<strong>and</strong>ardMP93BD Straight BT2003 Type 43 1 port 1MBB60912BAD 1 2 x straight BT2003 Type 43MP93BA Straight ST212 16 ports 1MBB60850AAG 2 32 x straight ST212MP93BB Straight HFE2290 16 ports 1MBB60891ABM 2 32 x straight HFE2290MP93BC Straight BT3002 St<strong>and</strong>ard 16 ports 1MBB60913ABB 2 32 x straight BT3002 St<strong>and</strong>ardMP93BD Straight BT3002 Type 43 16 ports 1MBB60913BBX 2 32 x straight BT3002 Type 43MP93CC 78 Way D Type Belden 9806 32 port 1MBB61426AAT 1 2 x D-typeEnd of section1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1506Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT16 POWER CONSUMPTION AND EQUIPMENT PROTECTION16.1 POWER CONSUMPTION FIGURESFigures for SMA1/4UC & EX specific cards are absolute maximums <strong>and</strong> are early estimates. SeeProduct Champion for latest figures.Cards/UnitsPowerConsumptionSMA1/4UC Specific1HAG60627AAV SMA1/4UC SUB RACK0W1HAT61107AAK/ABC 64x2M Core Trib Card 12.5W1HBA60827AAV 32x2M Unbalanced LTU –Interface module0W1HBA60828AAX 32x2M Unbalanced LTU –Front panel0W1HBA60831AAX 32x2M Balanced LTU –Interface module0W1HBA60832AAA 32x2M Balanced LTU –Front panel0W1HAM61217AAK Power/LCT LTU (9 pin) 0.5W1HAM61217ABC Power/LCT LTU (3 pin) 0.5W03HAN00007AAH AC Power & Battery Backup Unit (Maximum)TBCEX Specific03HAG00001AAX EX Subrack0W03HAM00008AAX EX Power/LCT LTU 0.5W03HAT00056AAQ EX 63x2M Trib Card23W (inc LTU)03HAM00003AAL EX 63x2M Unbal LTUN/A (see above)03HAM00002AAJ EX 21x2M Bal LTUN/A (see above)03HAM00009AAA EX Vertically Extended 63x2M Unbal LTUN/A (see above)UC & EX Generic1HAT61105AAF Core/CCU Card (including system memory module)19W1HAT61106AAH/BAE Comms/AUX/Ancillary Card12W1HAM61215AAF 3x34M LTU5W1HAM61218AAM Generic Trib Power LTU2W1HAT61114AAT Protection Core Card12W1HAM61219AAP Fan Assembly (SMA1/4UC)14W1400729-***** & 1400744-**** SFP Optical Line Module 0.8W4800943-0017 STM-1 Electrical Module DIN 1.0/2.3 1.0W1HAM61228AAC 2 x STM-1/140M LTU 5.0W03HAT00043AAU Multirate Trib Card11W03HAT00041AAQ STM-4/16 Core A/CCU ADM Unit26W03HAT00041ABH STM-4/16 Core B ADM Unit23WSMA Generic1HAT60622BAN 34Mbit/s Tributary Card without LTUs1HAT60623BAQ 45Mbit/s Tributary Card without LTUs1HAT60624BFE/CAP 140Mbit/s Tributary Card without LTUs1HAT60979AAC 34Mbit/s Transmux without LTU1HAT60791* STM-1 Optical Card TCM1HAT60878AAT Dual STM-1 Optical Card TCM without optical modulesSN66TQ,TR,TS,TT Quad STM-1 Optical Card for SMA-1/4c1HAT60803ABT STM-1 Electrical Card TCM with LTU1HAT60803ABT STM-1 Electrical Card TCM no LTU (i.e.: front access)1HAT61004ABP Dual STM-1 Electrical Card with LTUs1HAT61004ABP Dual STM-1 Electrical Card no LTUs (i.e.: front access)1HAT61059AAJ Quad STM-1 Electrical Card TCM (front access only)1HAT61008*** STM-4 Optical Card1HAT60876AAP Comms/Controller Card including SMC1HAT60877AAR STM1/4 ADM Card without optics, including LTU1HAT61052AAT STM1/4 ADM Card without optics, including LTU1HAT60988AAQ STM1/4 ADM Card without optics, including LTU12W12W8W11W7.7 W4 W12.0 W11 W8.8 W15.4 W11 W7.58 W8W10 W20 W20W20W1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1601Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT16.2 TYPICAL POWER CALCULATION1 x Subrack Core* = 19.5W *Core:- Core/CCU Card, Memory module <strong>and</strong> Pwr/LCTLTU2 x STM1 Optical modules = 1.6WProtection Core Card = 12W Switch protection64x2M Trib Card = 12.5W2 x 32x2M LTU = 0WDual STM1 Electrical Front access = 11WGeneric Trib Power LTU = 2WComms/Aux/Ancillary = 10W68.6W16.3 EXTERNAL PROTECTIVE DEVICE (EPD)The EPD (fuse or circuit breaker) for each of the –48V supply feeds to the equipment should beselected as follows.16.3.1 Type & LocationIf the EPD is to be located at the top of a rack containing heat-dissipating equipment then itshould be a temperature-compensated device such as a (Hydraulic) Magnetic Circuit-Breaker,or a temperature-compensated thermal or thermal-magnetic circuit-breaker.Fuses & non-compensated thermal & thermal-magnetic circuit-breakers should only be used in“end-of-suite” locations remote from racks containing heat-dissipating equipment.16.3.2 Device Parameter SelectionThe Breaking Capacity of the EPD must meet or exceed the Prospective Fault Current (I F ) atits load-side terminals.The Rated Current of the EPD should initially be selected to be the lowest available value thatexceeds the rated current of the subrack internal fuse. Internal fuse data are:• For UC: Belfuse Type SSQ-5, rated at 5A• For EX: Belfuse Type SSQ-12, rated at 12A• Data available at www.belfuse.comThe Rated Current of the EPD may be increased as a result of the following selection process,but should not exceed the current-carrying capacity of unprotected internal conductors in thesubrack. These are:• For UC: 16A (Power connector, 4A per contact)• For EX: 20A (PCB Copper - via holes supplying fuse)1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1602Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTThe time-current characteristic should now be selected to meet the following criteria:• The minimum energy let-through (I 2 t) of the EPD must be greater than the I 2 t valuerepresented by the equivalent time or current point of the inrush current limit curvegiven in ETSI EN 300 132-2 Clause 4.7.1 & Figure 2 (see www.etsi.org), for all valuesof I <strong>and</strong> t.For the purpose of this comparison the maximum input current I m as defined in EN 300132-2 is given by:VR(min)Im= IR(max). . . . . [1]48Where I R(max) & V R(min) are the maximum RATED CURRENT <strong>and</strong> minimum RATEDVOTAGE of the subrack, as given on the rating label & below:V R(min) = 38.4VFor UC: I R(max) = 4A, ⇒ I m = 3.2AFor EX: I R(max) = 9.5A, ⇒ I m = 7.6A• The minimum energy let-through (I 2 t) of the EPD must be greater than the maximumenergy let-through of the subrack internal fuse for any given value of I where I is lessthanor equal-to the Prospective Fault Current (I AN ) at the Power-LTU power connector,given that where the power cord has N conductors per supply pole (i.e. in the UC powercord), all such conductors are sound & the fault current is shared between them.• If the EPD is a Fuse then it must be further co-ordinated with the subrack internal fuseso that the EPD is not weakened if the internal fuse operates.• The guaranteed maximum disconnect-times of the EPD at I F , I A & at I AN must becapable of protecting the Power Cord, where I A & I AN are the Prospective Fault Currentsat the Power-LTU power connector when one or N conductors respectively per supplypole carry the fault current. NOTE: for power cords where N ≠ 1, I A assumes that asingle conductor carries the fault current in one pole, but all N conductors carry thefault current in the other pole.This is not expected to be a problem when using the cables recommended in section15.2 provided that the fastest time-current characteristic that meets all of the abovecriteria has been selected.Power Cord protection can be assessed using Equation 2 for faults anywhere within thePower Cord (desirable) & Equation 3 for equipment faults (m<strong>and</strong>atory). MeetingEquation 3 with N = 1 (I AN = I A ) protects the power cord against faults within its ownconnector.2 2 2k Sk . S . N5 ≥ TF≤ . . . . [2] 5 ≥ TAN≤ . . . . [3]2I2 2.2IFT F / T AN = disconnect-time of EPD in seconds at I F / I AN respectively. T x must be lessthan 5 seconds for formula to be valid: typical values are 1 - 30 ms.AN1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1603Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTk = Cable Factor. This is normally obtained from local Building Wiring Regulations inthe territory of installation, or from the cable manufacturer. For example, in the UK BS7671 gives a value of k = 100 for 90°C PVC cables with conductors operating atmaximum temperature (i.e. carrying the cable’s rated current taking into accountambient temperature de-rating factors).S = Cross-sectional area of an individual power cord conductor in mm 2N = Number of conductors per supply pole - (4 for UC, 1 for EX)I F / I AN = Prospective Fault Current at EPD / Power-LTU power connector16.4 MULTIPLE SUBRACK MOUNTING16.4.1 Mechanical considerationsThe subrack may be mounted in either the vertical or horizontal axis.In the vertical mounting option multiple subracks can be mounted in the vertical direction <strong>and</strong>up to 2 side by side horizontally. However, when doing so thermal aspects must be consideredas described in the following section.The st<strong>and</strong>ard Core UC subracks (SP03AB & SP13AB) comes supplied with brackets to allowall these mounting options.For horizontal mounting a fan must always be fitted. Please refer to Section 5.2.1.3 for full fantray equipping rules.Note:- The brackets meet the requirements for office vibration only. They have not beentested against extended requirements for earthquake zones.16.4.2 Thermal ConsiderationsIf required, it is permissible to mount more than one SMA subrack or other equipment in oneRack framework, however consideration must be given to:a) The maximum permissible power dissipation allowed in the customer’s rack framework.b) The maximum rise in temperature under which the upper SMA subrack will operate.c) The ETS Climatic Limits. The equipment has been tested as conformant to ETS 300 019-2Class 3.1e, which includes a working range of time operating at different temperatures <strong>and</strong>relative humidities.d) The reduced MTBF resulting from continuous operation at elevated temperature.e) Forced air-cooling.Guide to compliance:It is considered that with a maximum overall sub-rack power dissipation within a 19inch orETSI rack framework of up to 780W, the expected temperature rise over outside rackframework ambient would be no greater than 20DegC. This would be seen as the limit for rackequipping.Refer to important notes below:-1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1604Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTNOTE: Continuous operation at maximum ambient temperature is not recommended, it wouldbe expected that continuous operation would be at ambient temperatures less than 30DegC butoperation up to the maximum is allowable for short periods (Hours) as part of a weather or airconditioning plant failure – see c) above.NOTE: Operating a subrack in increased ambient temperature as normal deployment willreduce the Equipment MBTF.THE COMBINED POWER DISSIPATION OF ALL EQUIPMENT IN A RACK SHOULDBE CHECKED AGAINST MARCONI COMMUNICATIONS AND CUSTOMERINSTALLATION RULES.The use of multiple subracks with total power dissipation exceeding 780W should not normallybe used without forced air cooling or further environmental verification.Note: If the subrack is mounted horizontally then a fan tray should always be fitted. Pleaserefer to Section 5.2.1.3 for full fan tray equipping rules.End of section1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1605Issue 7


SMA1/4/16 UC & EX - PROVISIONING CONTROL DOCUMENT17 RELIABILITY17.1 SMA CARD MTBF PREDICTIONSThe following card figures are to be assumed for MTBF calculations. Engineering should beconsulted before any figures other than the MTBF (Spec.) are committed to a customer.Note :- MTBF (Spec.) = MTBF(HRD*) x 3 <strong>and</strong> may be offered to customers as the MarconiCommunications specification for MTBF. This multiplication factor is based on passedexperience of previous units calculated versus actual MTBF.Cards have MTBF calculated to HRD5 however some cards from early equipment werecalculated to HRD4.It should be emphasised that the figures below are from theoretical calculations only <strong>and</strong>are not based on actual field returns. Also the figures for the SMA1/4UC & EX specificMEs should be treated with caution.Note 1) These particular figures are rough estimates based on similar units <strong>and</strong> are not fromdetailed calculations.Note 2) Figure given is for the combined Interface <strong>and</strong> front panel unit, which together formthe LTU function.Cards/UnitsMTBFyearsHRD(*)MTBFyears(Spec.)SMA1/4UC Specific (Estimates based on current designs)1HAG60627AAV SMA1/4UC SUB RACK module (Note 1) 100 3001HAT61107AAK/ABC 64x2M Core Trib Card 20 601HBA60827AAV 32x2M Unbalanced LTU –Interface module (Note 2) 131.3 393.91HBA60828AAX 32x2M Unbalanced LTU –Front panel - -1HBA60831AAX 32x2M Balanced LTU –Interface module (Note 2) 138.88 416.641HBA60832AAA 32x2M Balanced LTU –Front panel - -1HAM61217AAK Power/LCT LTU (9 pin) (Note 1) 100 3001HAM61217ABC Power/LCT LTU (3 pin) (Note 1) 100 30003HAN00007AAH AC Power & Battery Backup Unit TBC TBCEX Specific03HAG00001AAX EX Subrack 81 24303HAM00008AAX EX Power/LCT LTU 640 64003HAT00056AAQ EX 63x2M Trib Card 14.1 42.303HAM00003AAL EX 63x2M Unbal LTU 9.5 28.503HAM00002AAJ EX 21x2M Bal LTU 42.2 126.203HAM00009AAA EX Vertically Extended 63x2M Unbal LTU 9.5 28.5UC & EX Generic1HAT61105AAF Core/CCU Card 15.43 46.291HAT61106AAH/BAE COMMS/AUX/Ancillary Card (Note 1) 20 601HAM61215AAF 3x34M LTU (Note 1) 50 1501HAM61218AAM Generic Trib Power LTU 50.0 150.01HAT61114AAT Protection Core Card 21.06 63.181HAM61219AAP Fan Assembly (SMA1/4UC) TBC TBC1400729-***** & 1400744-**** SFP Optical Line Module 50 1501HAL60517AAW STM-1 Electrical Module DIN 1.0/2.3 860.47 2581.411HAM61228AAC 2 x STM-1/140M LTU 29.4 88.203HAT00043AAU Multirate Trib Card 45 13503HAT00041AAQ STM-4/16 Core A/CCU ADM Unit 13.5 40.503HAT00041ABH STM-4/16 Core B ADM Unit 22.5 67.51ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1701Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTCards/UnitsMTBFyearsHRD(*)MTBFyears(Spec.)SMA Generic (Calculated figures)1HAT60791* STM-1 Optical Card TCM 20 601HAT60878AAT Dual STM-1 Optical Card without optical modules 21.69 65.07SN66TQ,TR,TS,TT Quad STM-1Optical Card for SMA-1/4c 25.16 75.481HAT60803ABT STM-1 Electrical Card TCM 21.1 63.31HAT61004ABP Dual STM-1Electrical Card 18.25 54.751HAT61059AAJ Quad STM-1Electrical Card TCM 40.15 120.451HAT61008*** STM-4 Optical Card1HAT60874* STM1 Dual Fibre Working Optical Module 28.1 84.31HAT61098* STM1 Dual Fibre Working Optical Module 28.1 84.31HAT60908* STM4 Dual Fibre Working Optical Module 28.1 84.31HAT60875* STM1 Single Fibre Working Optical Module 28.1 84.31HAT60909* STM4 Single Fibre Working Optical Module 28.1 84.31HAT60624BFE/CAP 140Mbit/s Tributary Card 35 1051HAM60798ABN/ACF/839AAN 140Mbit/s/STM-1 LTU & Link LTU 111 3331HAT60622BAN/623BAQ 34/45Mbit/s Tributary Card 34 1021HAT60979AAC 34M Transmux Card TBD TBDEnd of section1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1702Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENT18 STANDARDS AND APPROVALSNote: This section needs approval from SDA <strong>and</strong> Engineering. Discuss with ProductChampion before making any commitments to customers etc.The SMA-1/4UC & EX equipment meets the following specifications when all EMC <strong>and</strong>protective equipment rack covers are in position. Consideration should be given to the expectedworking conditions of the equipment when installed in an equipment rack, see Section 14 & 16for guidance.Electrical, Environmental <strong>and</strong> Safety Approval Testing has been performed considering:The SMA-1/4UC equipment is primarily rack-mounted equipment for use in telecommscentres.Approved racks are described in Section 14.4.The equipment is not approved for use in environments beyond the environmentalspecification. If alternative housing is required then the necessary advice <strong>and</strong> approval shall besought from the design authority <strong>and</strong> where necessary testing will be required.18.1 ENVIRONMENTAL SPECIFICATIONAtmosphericEquipment meets ETS 300 019-2In operation - Class 3.1EIn Storage - Class 1.1In transport - Class 2.3ElectromagneticProduct Family St<strong>and</strong>ard EN 300 386-2<strong>and</strong> European St<strong>and</strong>ardsES 201 468 Enhanced Availability of Service Level 2 including, but not limited to:Radiated Immunity - EN 61000-4-3 (10V/m)Radiated Emission - EN 55022 (Class B)DC Power Interface - ETS 300 132-2<strong>and</strong> British TelecommunicationsRequirements for telecommunication power requirements – BTR 2511 Iss0318.2 SAFETYIn order to comply with the safety requirements of EN60950, the equipment should beprofessionally installed in a restricted access location.1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1801Issue 7


SMA ULTRA COMPACT AND EXPANDED ULTRA COMPACT PROVISIONING CONTROLDOCUMENTNote: A protective earth connection must be made:Before any external cables are connected, the equipment must be connected to Protective Earth:The SMA1/4UC & EX shelf-frame shall be connected to protective earth via the shelf supportmetalwork. The frame must remain connected to Protective Earth until all external cables areremoved. Cards must not be removed or inserted with cables attached.The equipment has been designed to meet the general requirements of:-Health <strong>and</strong> Safety at Work Act 1974EN 60950BT Specification RC5000PMarconi Communications Product Safety Design Guide 1QDA 20090 AAY-YYA.18.2.1 Electrical SafetyThe equipment meets18.2.2 Optical SafetyEN60950: 2000AS/NZS60950: 2000ACA TS 001: 1997The optical source devices which are used in this equipment may have been classified by theirmanufacturers, under laser radiation safety st<strong>and</strong>ards EN 60825-1, as class 3M laser products,<strong>and</strong> so potentially can emit invisible optical radiation in excess of the inherently safe class 1limits defined by this st<strong>and</strong>ard.The use of these optical devices within the equipment, however, involves drive, powermonitoring <strong>and</strong> <strong>control</strong> circuitry to limit the power available from these devices, the design <strong>and</strong>setting up of the equipment ensures that the product meets the class 1 limits.No attempt should be made to adjust or tamper with the laser or its <strong>control</strong> circuitry as this mayresult in class 1 emission limits being exceeded.A safety interlock/shutdown mechanism is provided, which limits the emission duration of thetransmitted output power to a maximum of 4.6 seconds in the event of a fibre breakage.Two discrete <strong>control</strong> loops are provided to ensure that the output power cannot exceed itsspecified operating limits. In the event of a fault occurring, these loops remove power from thelaser drive circuitry.Refer to the SMA H<strong>and</strong>book warnings <strong>and</strong> operating instructions for guidance on laser<strong>and</strong> other hazards.18.3 REPORTSReports have been produced to support the compliance <strong>and</strong> approval of the SMA equipment(e.g. Thermal Analysis /Environmental/EMC/Safety Reports).End of sectionEND OF DOCUMENT1ADR 60773 AAC-CTA Copyright - Refer to Title Page Page 1802Issue 7